7 LCD Operation
Touch ESC to add the value and Touch ENT to
move the cursor. Press ENT to confirm the setting.
The "+" can be changed to "-" by touching ESC.
The adjustment rangs from -9999 kWh to +9999
kWh.

7.5.8 Setting Communication Parameter

Touch ESC to set the appropriate value and touch
ENT to move the cursor. Confirm settings by
pressing ENT.
Device address range: 1-247.

7.5.9 Ethernet Configuration

The Ethernet setting is reserved for later usage.
Touch ENT to select and press ENT to confirm.
OFF: The IP address should be assigned manually.
ON: Automatically assign an IP address from the
home router.
Touch ESC to switch between the DHCP and the IP
interfaces.

7.6 Starting/Stopping the Inverter

Main Screen (Press ENT)→Menu (Touch ESC)→ON/OFF (Press ENT)
Touch ENT / ESC to select and press ENT to
confirm.
Confirm your selection by pressing ENT.
52
Confirm turn on?
User Manual
+0000 kWh
Modbus ID: 001
DHCP:
OFF
ON
IP:
192.168.001.100
ON
OFF
Confirm turn off?