Sungrow SG2K-S User Manual page 76

Pv grid-connected inverter
Hide thumbs Also See for SG2K-S:
Table of Contents

Advertisement

10 Appendix
Parameters
Operating ambient temperature
Allowable relative humidity
Cooling method
Max. operating Altitude
Display
Communication
PV connection type
AC connection type
Certification
Mechanical Data
Dimensions (W x H x D)
Mounting method
Weight
Parameters
Input Data
Max. PV input power
Max. PV input voltage
Startup voltage
Nominal input voltage
MPP voltage range
MPP voltage range for nominal
power
No. of MPPTs
Max. number of PV strings per
MPPT (PV1/PV2)
Max. PV input current
Max. current for input connector
Short-circuit current of PV input
Max. inverter backfeed current to
PV string
Output Data
Nominal AC output power
Max AC output apparent power
Max. AC output current
Max. inrush current
(peak value / duration)
Max. output fault current
(peak value / duration)
Max. output over-current protection
68
SG3K-D
-25℃ to +60℃
0–100 % (non-condensing)
Natural cooling
4000 m (derating when > 2000 m)
Graphic LCD
Wi-Fi
MC4
Plug and play connector
IEC 62109-1, IEC 62109-2, IEC 62116,
IEC 61727, EN 61000-6-2, EN 61000-6-3,
AS4777.2, ABNT NBR 16149, ABNT NBR
16150,
VDE-AR-N-4105,
VDE0126-1-1, UTE C15-712, VFR-2014,
EN50438, C10/11, G83/2, G59/3
300 mm x 370 mm x 133 mm
Wall-mounting bracket
11.5 kg
SG5K-D
6500 W
600 V
120 V
360 V
90 V–560 V
260 V–480 V
2
1/1
20 A (10 A / 10 A)
24 A (12 A / 12 A)
24 A (12 A / 12 A)
0 A
5000 W
5000 VA
22.7 A
10 A / 12 ms
100 A / 3.2 ms
32 A
User Manual
SG4K-D
CEI
0-21,
SG6K-D
7800 W
315 V–480 V
6000 W
6000 VA
27.3 A

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SG2K-S and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Sg3k-sSg3k-dSg4k-dSg5k-dSg6k-dSg8k3-d

Table of Contents