Parameter Setting - Sungrow SH8.0RT User Manual

3-phase hybrid inverter
Hide thumbs Also See for SH8.0RT:
Table of Contents

Advertisement

8 iSolarCloud App
Select Customized Charging to enter the Add Preset Condition interface, drag to set the
charging start time and end time, input Current and Charging Power, and tap Save. It will
jump to the customized charging interface. TapSave again to finish setting.
The minimum unit of charging time is 10 minutes.
The current is the maximum allowable current of the EV-Charger to charge the on-board
system, and the charging power is the maximum allowable charging power of the EV-
Charger to charge the on-board system. The current and the corresponding charging
power can be set as follows:
Current
(A)
Power
(kW)
In this mode, the EV-Charger starts charging automatically at the set charging
time.
If the moment is within the set charging time and the charging cable has been
inserted into the EV, click "Save" on the charging mode interface and the EV-
Charger will immediately start charging the EV.

8.11.3 Parameter Setting

Tap Settings to enter the corresponding interface.
114
figure 8-23 Customized Charging
6
8
4.14
5.52
10
12
6.9
8.28
User Manual
14
16
9.66
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents