C08-Calibration; Calibrate The Scale - ISHIDA Uni-3 Technical Manual

Price computing scale with printer
Hide thumbs Also See for Uni-3:
Table of Contents

Advertisement

Parameter
C07-04
C07-04-01 Sensor Type
Label Feed
C07-04-03 Label Sensor Level & Sensitivity Enter a value to adjust the label sensor.
C07-04-04 Label Gap Detect
C07-04-05 Pre-Print Length
C07-04-06 Label Sensor Distance
CO7-04-07 Back Feed
C07-04-08 Peel Sensor
4.8

C08-Calibration

Set the scale's capacity and range and calibrate the weight readings.
Display
C08-01 Capacity
C08-02 Range
C08-03 Area Setting
C08-04 Advanced Setting
C08-09 Initialize
C08-10 Span Calibration

4.8.1 Calibrate the Scale

1. Remove any objects from the platter and press the
2. Place full capacity weight on the scale, example 30 lb.
3. Press
. Display reads: Span= 80000, Weight= 30.00.
Tare
68
Uni-3 Technical Manual
Display
Table 4-5. C07 Printer Parameters (Continued)
Specifies the scale's maximum capacity and units.
Changes to the capacity selection will not be saved until
Note
calibration is performed.
Do not select 60 lb (or 30 kg) unless the scale is
CAUTION
equipped with a high capacity load cell.
Specifies the accuracy of the scale.
Example: Single: 0-30 x 0.01 lb Multi: 0-15 x 0.005 lb, 15-30 x 0.01 lb
Changes to the range selection will not be saved until a
Note
calibration is performed.
Gravity setting. Used when the scale is calibrated in one location and used at
another. This step is password protected.
Enables steps C08-05 to C08-08. Used for factory verification.
Initializes calibration parameter. All settings are reset to default values after
initialization. To store settings again, perform the zero point adjustment and
the span adjustment. Press the span button to store the settings.
Use this function only when calibration is not operating
Note
normally.
See Section 4.8.1 below.
Table 4-6. C08 Calibration
Description
Specifies if the Label Gap sensor is active.
• Backing Paper Only: Approximately 150
• Backing Paper and Label: Approximately 50
Adjusts the threshold value of the label gap
sensor. Any sensor readings below the set value
are ignored. This is useful when the label has
dark pre-printed areas that affect the sensor
output.
Adjusts the length of the preprint section. Specify
the length in 0.1 millimeters. Default is 7.5 mm.
Specifies the distance between the label gap
sensor and the print elements on the thermal
head. Specify distance in 0.1 millimeters. Default
is 71.0 mm.
Turns the backward feeding on or off.
Specifies if the peel sensor is active.
CO8
CALIBRATION
Description
key. Display reads: Span= 20000, Weight= 0.000.
Zero
Choices
0: NONE
1: LABEL
0-255
0-255
--
--
1: NO
2: YES
0: USE
1: NO USE
Choices
0: 15 kg
1: 30 kg
2: 30 lb
3: 60 lb
9: 30 kg (1/6000)
0: SINGLE
1: MULTI
--
1: OFF
2: ON
--
--

Hide quick links: