Appendix; Error Codes - ISHIDA Uni-3 Technical Manual

Price computing scale with printer
Hide thumbs Also See for Uni-3:
Table of Contents

Advertisement

6.0

Appendix

6.1

Error Codes

For the single-line Uni-3L1 in some cases pressing the Up or Down arrow keys will toggle between the error
Note
number and the description.
Error No.
105
Initialization Failed
106
Battery is Fault
108
Clock Setting is Not Completed Yet
109
Printer 1 Initialization Was Not Done Yet
110
Machine Setting Is Not Completed
111
The Display Confirmation Is Not Completed
112
The Confirmation Of The Key Is Not Completed Perform key check, see Section 4.4 on page 65
114
The Data Composition Is Different
116
The Country Has Not Been Selected
202
PLU Master Is Not Programmed
203
POP Master Is Not Programmed
212-216
Free Master Isn't Registered
219
Store Master Is Not Programmed
221
Tare Limit Over (g)
222
Tare Weight is 0 g
223
Label Setting Master Is Not Programmed
266-000
File Input Error
266-001
File Input Error
267-000
File Output Error
267-001
File Output Error
268-000
File Delete Error
268-001
File Delete Error
268-002
File Delete Error
268-003
File Delete Error
271
Initialize Error
275
Extra Message 1 not found
276
Extra Message 2 not found
277
Extra Message 3 not found
281
Tare Limit Over (kg)
282
Tare Weight is 0 kg
283
Tare Limit Over (lb)
284
Tare Weight is 0 lb
312-000
Label Is Remaining
313
Printer Thermal Head Is Up
316
Markdown Price Is More Than Original Price
321
Price Is Not Programmed
Error
Perform memory initialization, see Section 4.6 on page 66
Verify battery switch is on or replace battery
Set up clock, see Section 4.2 on page 65
Initialize printer one, see Section 4.7 on page 67
Select machine type, see Section 4.11 on page 70
Perform key check, see Section 4.4 on page 65
Initialize the memory, see Section 4.6 on page 66
Select country, see Section 3.20 on page 57
Check PLU number, program if necessary,
see Section 5.1 on page 72
Check POP number, program if necessary,
see Section 5.13 on page 81
Check Free Message, register if necessary,
see Section 5.16 on page 82
Check store number, program if necessary,
see Section 5.6 on page 78
Re-program tare weight
Set tare weight
Check label number, program if necessary
There is a file that failed during input, check USB
Failed in reconstruction of SRAM data
There is a file that failed during output, check USB
Failed in SRAM data backup
There is a master file that failed in deleting
Failed in SRAM delete
Failed in Data delete
There is data that failed in deleting
There is master data that failed in initialization
The extra message 1 linked to the PLU does not exist. This error
message can be disabled at step B18-02-03.
The extra message 2 linked to the PLU does not exist. This error
message can be disabled at step B18-02-04.
The extra message 3 linked to the PLU does not exist. This error
message can be disabled at step B18-02-05.
Re-program tare weight
Set tare weight
Re-program tare weight
Set tare weight
Remove label or check peel sensor levels,
see Section 4.7 on page 67
Put thermal head down
Check price, markdown should be less than original price
Enter price, program if necessary
Table 6-1. Error Codes
Description
Appendix
83

Hide quick links: