Stopping the engine DFG
– Set the ignition / starter switch (19)
to "0".
– Remove the key from the ignition /
starter switch (19).
Stopping the engine TFG
– Close the shut-off valve (42) of the
LPG bottle securely.
– Wait until the engine comes to a stop.
– Turn the ignition / starter switch (19)
to "0".
– Remove the key from the ignition /
starter switch (19).
M
If the ignition key is set to "0" while
the engine is running, the engine will
continue to run for a short time. This
ensures that the remaining gas in the
lines between the engine and the
automatic shutoff valve of the gas
system is used up.
o
Steel cab
For trucks fitted with a steel cabin, both
doors can be closed.
– To unlock the cabin door turn the key
anti-clockwise.
– To lock the cabin door turn the key
clockwise.
– To open the cabin door, unlock the
door and remove the handle (43).
E 34
19
42
43