Reusable LPG bottles with central filling device
F
Refillable liquid gas bottles contain a
dispensing valve (10), a filling stop
valve (11), a relief valve (12) and a level
display (13). To fill the tank close the
dispensing valve, unscrew the cover of
the filling stop valve and insert the
nozzle of the LPG pump into the filling
port. The filling stop valve automatically
stops the gas from being filled when the
bottle reaches the maximum level.
At filling, screw the lid back on. Observe
any guidelines or regulations on filling
LPG bottles that are attached to the
LPG pump.
Z
Safety notices :
- Do not carry out any work on the tank.
Repairs must only be carried out by trained personnel
- The user must always check the fittings for damage and wear before using the tank
- The tank and the fittings must be checked regularly for physical damage, corrosion
and other damage in accordance with the regulations of the country of use.
Lift trucks with two LPG bottles
F
A twin LPG bottle container may only be used if the truck is equipped with an
operational reverse camera system and outer mirrors on both sides.
Z
A supply valve is also attached to the unit in addition to the shutoff valves on both gas
bottles. This valve can be used to select from which of the two bottles the gas is to be
taken. The two bottles cannot be used together.
M
Close both shutoff valves on the gas bottles to interrupt the supply of gas.