"Rotarex" gas limit display operating instructions
Functional description
The gas limit display is a threshold device for
the fluid phase, known as an MLD (Minimum
Liquid Detector). The MLD indicates when
there is just a small amount of gas left in
the container. The remaining travel time will
then depend on the application and ambient
conditions. Normally it is 8 - 12 minutes. This
is then displayed via the spare indicator (2) on
the dashboard.
Z
Note: if the container level is low, the spare
indicator can briefly light up or flicker due to
fluctuations in the liquid gas level produced
during travel. Only when the indicator is permanently lit does this indicate that the tank
is almost empty.
M
Safety Notices
- All maintenance, assembly and disassembly of the MLD fitting must be carried out
solely by qualified personnel trained in gas systems. Such personnel must have
detailed knowledge of ECE R67-01 and/or Directive 97/23/EC and all standards and
regulations referred to therein.
- The user is responsible for the cleanliness of the container used. It must be free of
grease, metal particles, plastic particles or anything else that could hinder the
operation of the valve.
- The MLD must not be subjected to impacts or other mechanical effects. It is
prohibited to continue using bent or otherwise damaged fittings.
- It is prohibited to approach the Propane/Butane installation with fire or a naked
flame
- The markings on the fitting must not be removed or altered.
- All users must strictly observe national and regional regulations on assembling and
using Propane/Butane gas valves.
- The user is responsible for all accidents and material or non-material, direct and
indirect damage caused by improper handling and servicing or non-authorised use.