4 .2 Function Specifications

Function Specificationsr
Item
Display screen
EU (scaling function)
Functions during capture
Data save function
Capture
function
Ring capturing Capturing destination: Internal RAM/Internal memory/USB memory/SD card
Relay
capturing
Backup function
Backup
destination
Sampling
interval
USB memory
SD card
Statistical calculation
(Real time)
Statistical calculation
(Between cursors)
Search functions
Annotation enter function
Waveform + Digital screen
All Waveform screen
Logging + Calculation Display screen
X-Y screen
* It is possible to open the menu even during capturing (Setting is impossible, for
confirmation)
* Switching by dedicated key (Toggle operation)
Voltage, Root mean square value : 4 points can be set for each channel
Temperature, Humidity : 2 points can be set for each channel (Offste function)
Pulse : 2 points can be set for each channel (Gain function)
Replaying the data during capturing
Capturing destination: Built-in RAM/Internal memory/USB memory/SD card
Captured data: Settings, Screen data, Measurement data
Function: OFF, Ring recording, Relay recording
Number of capturing points: 1,000 to 10,000,000
(No need to set the number of capturing points when using Internal RAM)
Sampling interval: Internal RAM maximum speed 1 μs/other fastest 1 ms (10 ms at
capturing with CSV)
Capturing destination: Internal memory, USB memory/SD card
Sampling interval: Fastest 1 ms (10 ms at capturing with CSV)
Function: OFF, 1, 2, 6, 12, 24 hours; specified time
* In addition to the above, backup can be performed by key operation
Internal memory, USB memory, SD card, FTP
Fastest 1 ms (10 ms at capturing with CSV)
Function to replace the USB memory for backup destination
Function to replace the SD card for backup destination
Types of operation: Maximum value, minimum value, P-P value, Average value
Number of calculations: 4 arithmetic operations are displayed simultaneously.
Calculation method: Free running, during capturing)
Sampling interval: No limit (fastest 1 μs)
Types of operation: Average value, maximum value, minimum value, P-P value, root mean
square value
Number of operations: 5 arithmetic operation results are displayed simultaneously.
Calculation method: Calculation between cursors (during replaying)
Function: Searches for the target point in the captured data.
Search type: Search by level of each channel
search by logic pulse + combination
search by generated alarm
Function : A comment can be entered for each channel
Enterable characters : Alphanumeric characters
Number of characters : 31
Description