I/O problem on connected FCoE device (CNAs only)

There is an I/O problem on a connected FCoE device.
1. Possible Cause: Link between the CNA and switch is down.
2. Possible Cause: PFC (priority flow control), CEE Map, and FCoE Map is not configured correctly
32
Action: Execute the Fabric OS licenseshow command on the connected switch to determine if
the license is installed. Install license if not installed. For more information about Fabric OS
commands and QoS support, refer to the Fabric OS Administrator's Guide.
Action: Verify that the CEE status using the BCU port –list command is displayed as "CEE
Linkup". If "Linkdown" or "Linkup" displays, refer to
Action: Verify if VLAN on front-end port is FCF-capable using the appropriate Fabric OS
command on the attached switch. Refer to the Fabric-OS Command Reference Manual for
more information.
Action: Set the VLAN as FCF-capable using the appropriate Fabric OS commands on the
attached FCoE switch. Refer to the Fabric-OS Command Reference Manual for more
information.
Action: Verify if the FC-MAP on the switch is set for a VLAN with FCF capability using appropriate
Fabric OS command on the attached switch. Refer to the Fabric OS Command Reference
Manual for more information.
Action: Set the FC-MAP for a VLAN with FCF capability using the appropriate Fabric OS
command on the attached switch. Refer to the Fabric OS Command Reference Manual for
more information.
VF-Ports to be part of the login group.
Action: Verify if FCoE Login group is created on switch using the appropriate Fabric OS
command. Refer to the Fabric OS Command Reference Manual for information.
Action: Create an FCoE login group on the switch using the appropriate Fabric OS command.
Possible Cause: PFC (priority flow control), CEE Map, and FCoE Map is not configured correctly
on the FCoE switch.
Action: Refer to
"CEE is not enabled"
Action: Refer to
"FCoE link is down (CNAs only)"
Action: Refer to
"CEE is not enabled"
on the FCoE switch.
Action: Verify configuration using the appropriate Fabric OS command on the attached switch.
Refer to the Fabric OS Command Reference Manual for information.