Adapter driver event messages
TABLE 13
Driver event messages (continued)
Message
Remote port (WWN = [remote port
WWN]) offlined by logical port (WWN
= [logical port WWN]).
Remote port (WWN = [remote port
WWN]) connectivity lost for logical
port (WWN = [logical port WWN]).
Target (WWN = [Target WWN]) is
online for initiator (WWN = [Initiator
WWN]).
Target (WWN = [Target WWN])
offlined by initiator (WWN = [Initiator
WWN]).
Target (WWN = [Target WWN])
connectivity lost for initiator (WWN =
[Initiator WWN]).
Virtual port deleted using proprietary
interface: WWN = [logical port WWN],
Role: [initiator, target, IPFC mode
etc.].
Virtual port deleted using standard
interface: WWN = [logical port WWN],
Role: [initiator, target, IPFC mode
etc.].
Virtual port login failed. Duplicate
WWN = [logical port WWN] reported
by fabric.
Virtual port (WWN = [logical port
WWN]) login failed. Max NPIV ports
already exist in fabric/fport.
Virtual port (WWN = %s) login failed.
Network and Storage Driver Events
Adapter removed: SN = [adapter
serial number].
Authentication successful for base
port: WWN = [base port WWN or
MAC].
102
Severity
Event Type
Information
Storage driver
Error
Storage driver
Information
Storage driver
Information
Storage driver
Error
Storage driver
Information
Storage driver
Information
Storage driver
Warning
Storage driver
Warning
Storage driver
Warning
Storage driver
Warning
Network and
storage driver
Information
Network and
storage driver
Category
Sub
Cause
Category
4 (RPORT)
Offline
Login nexus with
remote port
terminated by
logical port.
4 (RPORT)
Offline
Login nexus with
remote port is lost.
5 (ITNIM)
Online
SCSI IT-Nexus
established
between initiator
and target.
5 (ITNIM)
Offline
SCSI IT-Nexus
terminated by
Initiator.
5 (ITNIM)
Offline
SCSI IT-Nexus
terminated between
initiator and target.
3 (LPORT)
Deleted
Virtual port deleted.
3 (LPORT)
Deleted
Virtual port deleted.
3 (LPORT)
Failed
Duplicate WWN
reported by fabric.
3 (LPORT)
Failed
Max NPIV ports
already exist in
fabric/fport.
3 (LPORT)
Failed
Unknown error.
1
Removed
Adapter removed.
(Adapter)
2 (Port)
Successful
Authentication
successful.
Brocade Adapters Troubleshooting Guide
Action
No action
required.
Check if remote
port is having
issues.
No action
required.
No action
required.
No action
required.
No action
required.
No action
required.
Delete this vport
and create with a
different WWN.
Check fabric and
fport
configuration
Check
fabric/fport
configuration.
Check PCIe
connector and
configuration.
No action
required.
53-1001582-01