TABLE 14
Message
You are going to stop the
pending test(s) only.
All Started test(s) will
continue to run. Are you
sure you want to
continue?
The External Loopback
Test requires a
plugged-in loopback
cable; otherwise, the test
will fail.
Unexpected Error. Test(s)
will be stopped.
No tests have been
selected. Select one or
more tests.
You are about to delete
all the test logs. Are you
sure you want to
continue?
Unexpected Error. eth
Loopback Test will be
stopped. Please contact
the technical support
Unable to find the host.
Please provide another
host.
Failed to connect to the
Agent
Unable to find the host.
Please provide another
host.
Enter a valid host name
or IP address
Provide a port number in
the range [1025-65535].
Refresh cannot be
performed while the
Event Properties dialog is
open.
Brocade Adapters Troubleshooting Guide
53-1001582-01
Host Connectivity Manager messages (continued)
Cause
This occurs when the user stops a diagnostics
test before it finishes.
Occurs when the user selects external loop
back test
Occurs when the user tries to execute the
diagnostics test when the agent is stopped.
Occurs when the user clicks Start without
selecting any test
Occurs when the user selects a test log and
selects option to clear the log.
Occurs when the user executes the loopback
test for a port and connection is lost.
Occurs when an invalid host name or IP
address is given in Host Name field in the
Setup for Discovery dialog box.
Occurs when the agent connection is lost.
Occurs When scoped link local ipv6 address
(such as fe80:216:cbff:fea9:c3b5%en0 or
fe80:216:cbff:fea9:c3b5%3) is provided in the
Setup for Discovery dialog box.
Occurs when the user clicks Add button in the
Syslog Server Configuration dialog box without
providing any host name or IP address or by
providing an invalid host name or IP address
Occurs when the user provides a port number
out of the range (1025-65535) in the Setup for
Discovery dialog box.
Occurs when the Event Properties dialog box is
kept opened and the user tries to refresh the
master log.
HCM and Installer Message Reference
Corrective Action or Notes
Information message.
Plug in a loopback cable, and then
run external loopback test to
complete it successfully.
Start the agent, and then execute
the diagnostics test
Select a test, and then click Start.
Warning. This clears all the test logs.
Verify the connection, and then
proceed with loopback test.
Enter a valid host name or IP
address in the Host Name field.
Start the HCM agent service, and
then proceed.
Provide the IPv6 address without
using the scope-id and the delimiter
(%). Just use
fe80:216:cbff:fea9:c3b5.
Enter a valid host name and IP
address in the host name field of
the Setup for Discovery dialog box.
Enter a valid host name/IP address
in the Host name/IP address field of
Syslog Server Configuration dialog
box.
Enter a port number between 1025
and 65535.
Close the Event Properties dialog
box, and then click Refresh to
display updated values.
B
107