Alarm signals

In the event of a working defect, the system informs the user about the type of failure occurred.
The following table summarises the alarms, kind of problem and possible solution:
Display
ALAR 1
BLACK OUT
PROBE
ALAR 2
EXHAUST
HOT
ALAR 3
EXHAUST
FAN
ALAR 4
FAILURE
NO
ALAR 5
LIGHTIN
NO
ALAR 6
PELLET
SAFETY
ALAR 7
THERMAL
FAILURE
ALAR 8
DEPRESS
SERV
Regular checks should be carried out by the user, who should only contact the Authorized
Assistance Center if no solution is found.
Kind of problem
There is no power supply
The smokes sensor is broken or
not connected to the pcb
Smokes temperature too high
Smokes extractor blocked or
broken
The Insert cannot start up
This is the rst light-up
The pellet Insert switched off
while working
The water temperature exceeds
100°C.
Obstructed ue
The
Insert
has
worked
1200
hours.
Supplementary
maintenance required
As soon as the power supply is back, the Insert
starts a cooling cycle: it will be necessary to
restart it manually
Contact an Authorized Assistance Center
Switch off the Insert, allow it to cool down
and perform ordinary cleaning. If the problem
persists, contact an Authorized Assistance
Center for cleaning the Insert and the ue
Contact an Authorized Assistance Center
Fill in the tank with pellets
Start up again
Fill in the tank with pellets
Clean the inert and the ue. Reset the thermost
manually. If the problem persists, contact an
Authorized Assistance Center
Clean the ue or check there are no obstructed
grids near the smokes exhaust
for
Contact an Authorized Assistance Center
Solution