Kalor Alessia User Manual

Kalor Alessia User Manual

14b – boiler stove

Advertisement

USER MANUAL
Alessia/Mara 14B – Boiler Stove
Instructions for the correct use and maintenance of
your Kalor wood pellet stove
Distribution and warranty in Ireland by:

Advertisement

Table of Contents
loading

Summary of Contents for Kalor Alessia

  • Page 1 USER MANUAL Alessia/Mara 14B – Boiler Stove Instructions for the correct use and maintenance of your Kalor wood pellet stove Distribution and warranty in Ireland by:...
  • Page 2 Thermostove 15 Dear Customer, Cod. 001143 We thank you for having chosen one of our products, the fruit of technological experience and of continual research for a superior quality product in terms of safety, dependability, and service. In this manual you will find all the information and useful suggestions to use your product with the maximum safety and efficiency.
  • Page 3 Norms and declarations of conformity Our company declares that the stove conforms Responsibility to the following norms for the EC European Directive labelling: With the delivery of the present manual, we • 2014/30 UE (regulation EMCD) and following decline all responsibility, both civil and penal, for amendments;...
  • Page 4 • Use only wood pellets; • Keep / store the pellets in a cool dry place; • Never pour pellets directly on the hearth; • The thermostove must only with quality 6 mm diameter pellets of the type recommended by the manufacturer; •...
  • Page 5 Instructions for safe and efficient use • The device can be used by children that are not • The thermostove must be connected to an less than 8 years old and people with reduced electrical system equipped with an earthing physical, sensory or mental capabilities, or lack conductor in accordance with regulations 73/23 of experience or knowledge, provided being...
  • Page 6: Operating Area

    Operating area For proper functioning and a good temperature distribution, the stove shoul be positioned in a location where it is able to take in the air necessary for combustion of the pellet (about 40 m /h must be available), as laid down in the standard governing the installation and in accordance with local national standards.
  • Page 7 Connection to the flue pipe draught between 10 Pa and 12 Pa. At the botton of the flue pipe, provide an inspection cap to allow periodic checking and cleaning, which The flue pipe must have internal dimensions not larger than 20x20 cm, or diameter 20 cm. In the must be done annually.
  • Page 8 Fireplace flue gas Avoid contact with combustible materials (example: wooden beams) and in any case provide for their insulation with flame retardant material. In case of pipe penetrations through roofs or walls is recommended to use special kits crossing, certificates, are available commercially. In the event of a chimney fire, turn off the stove, disconnect from the network and never open the door.
  • Page 9: Remote Control

    REMARKS: - the appliance must be installed by a qualified technician in possession of the technical and professional requirements according to the DM37/2008 that, under its responsibility, to ensure compliance with the rules of good technique. - the thermostove must be connected to a heating system and/or to a network of production of sanitary hot water, consistent with its performance and its power - you need to keep in mind all laws and national, regional, provincial and municipal laws of the country in which you installed the device...
  • Page 10: Technical Specification

     Technical Specification                              N.B.: measures with a tolerance of about 10 mm ...
  • Page 11 PARAMETER M. UNITS NSAT150 Heat input 14,79 Nominal heat output 13,84 Reduced heat output 5,04 Water heat output 10,53 Reduced water heat output 3,81 CO concentration at nominal reference (13% O mg/m 230,7 CO concentration at reduced reference (13% O mg/m 299,2 Nominal efficiency...
  • Page 12 Configuration of the hydraulic diagram of the boiler BY A SPECIALIZED TECHNICIAN Before starting the boiler, it is necessary to configure the hydraulic scheme on which we want to work. The boiler is set up to receive the clean contact of an external thermostat (open / closed, the thermostat must not give tension to the back. If the thermostat carries voltage to the board causing faults, the warranty is void), two temperature probes and a motorized valve .
  • Page 13 Following the principles of operation of the various hydraulic diagrams. Important considerations: • healthcare will always have priority • There are three types of stand-by: Type 01: the ambient temperature detected by the probe on the board has reached the SET AIR set Type 02: the water temperature in the boiler has reached the SET H2O set Type 03: the external thermostat has detected that the desired temperature has been reached and therefore the contact is open.
  • Page 16 Directions for use Filling the thermostove funding of sanitary kit If the installation of the thermostove provides Once all the water connections, proceed to interaction with another existing system check pressure seal by filling the thermostove. complete with a heater (gas boiler, gas boiler, oil During this operation, any air in the system is released from the automatic vent valve.
  • Page 27 Accensione Caldaia Remove any components which might burn from the firebox and from the glass (various instructions and adhesive labels) Charge pellet Fuel is loaded from the upper part of the boiler by opening a door. Pour the pellets in the hopper. When empty, this is easier if performed in two steps: •...
  • Page 28 Preliminary checks Before switching on the pellet boiler, make sure that the pellet hopper is full, the combustion chamber is clean, the glass door is closed, the power supply plug is connected and the switch on the back is set to “1.” Informazioni sul display TURNED OFF 21 : 10...
  • Page 29 Alarm signals In the event of a working defect, the system informs the user about the type of failure occurred. The following table summarises the alarms, kind of problem and possible solution: Display Lower Kind of failure Solution Superiore Display The boiler cannot start up Fill in the tank with pellets ALAR...
  • Page 30 Menù programmazione Menu 02 SET CLOCK To access the set clock option, press the “SET” button (3), with the button - (5) scroll through the submenus until MENU 02 - SET CLOCK and with buttons 1 and 2 select the current day. Press the “SET” button (3) to confirm. Then use buttons 1 and 2 to set the time and press “SET”...
  • Page 31 level 1 level 2 level 3 level 4 value 03 - set thermostat 01 - activate thermos. 01 - activate thermos. on/off 02 - day programme 01 - daily thermostat on/off 02 - start 1 day hour 03 - stop 1 day hour 04 - start 2 day hour...
  • Page 32 35 - friday prog. 4 on/off 36 - saturday prog. 4 on/off 37 - sunday prog. 4 on/off 04 - week-end program. 01 - therm. week-end 02 - start 1 03 - stop 1 04 - start 2 05 - stop 2 input livello di menù...
  • Page 33 PROGRAMME 1 PROGRAMME 2 menu level selection meaning possible values menu level selection meaning possible values 02-03-02 START PROGRAM 1 activation time time - OFF 03-03-11 START PROGRAM 2 activation time time - OFF 02-03-03 STOP PROGRAM 1 shut-off time time - OFF 03-03-12 STOP PROGRAM 2...
  • Page 34 Failure on electrical devices Failed light-up If the flame does not light up during the switching on or if the smokes temperature does not reach a suitable value in “A l ar No A cc the foreseen time gap, the boiler switches off and you will read the words on the display.
  • Page 35 Water Characteristics The characteristics of the water used to fill the system are very important to prevent the build-up of mineral salts and the formation of incrustations along the pipes, in the boiler and in the heat exchangers. Therefore, please get your plumber’s advice concering: •...
  • Page 36: Safety Devices

    Safety devices Pressure switch: monitors Reduction motor: Flue temperature Electrical safety: sensor: thermocouple that depression in the smoke if the motor stops, the stove is protected against duct. It is designed to shut thermostove continues to measures the temperature violent surges of current down the pellet feed screw function until the flame goes of the fumes while keeping...
  • Page 37 Failure on electrical devices Failed light-up Manual restart thermostat If the flame does not light up during the switching on or if the smokes temperature does not reach a suitable value in the foreseen time gap, the thermostove switches off and RESTART you will read the words “Ala r No A cc”...
  • Page 38: Maintenance And Cleaning

    Maintenance and cleaning All cleaning of all parts must be carried out with the stove com- pletely cold unplugged avoid burns thermal shock. The stove does not need much maintenance if used with certified quality pellet. The need for maintenance varies depending on the conditions of use (switching on and off repeatedly) and depending on the performance required.
  • Page 39 and optimal operation of your thermostove. Do not use abrasive products and When positioning the crucible, carefully check do not spray the cleaning product that the ends of the pads completely adhere to on the glass of the painted parts their home and that the hole with pipe dedicated or on the gaskets of the fire door to the passage of the resistance.
  • Page 40 Check every 3-4 sack of pellets burned Before placing the thermostove in storage, you should remove all pellets from the hopper with Clean bottom ash from the fallen debris during a vacuum cleaner with a long extension. If the operation. You can access the ash pan by fuel is left in the hopper, it may get damp, stick loosening the two wing nuts that hold the drawer...
  • Page 41 The check of electromechanical components must be performed only by qualified personnel with technical knowledge of electricity and combustion. We recommend that an annual maintenance service is carried out, preferably under a programmed service contract. The essential part Now the upper section to the heat exchanger of this service is a visual and functional check on is free from any encumbrance so as to the following components:...
  • Page 42 Any kind of tampering or unauthorized substitu- The use of aggressive detergents or tion of non-original of the thermostove can be thinners can damage the surfaces hazardous to the safety of the operator and re- of the thermostove. Before using lieves the manufacturer from any civil or criminal any detergent it is advisable to try it on liability.
  • Page 43 Problems and solutions All repairs must be carried out exclusively by a specialised technician, with the stove completely cold and the electric plug pulled out. Is prohibited from any unauthorized modification to the device and the replacement of parts with other non-original. The operations marked in bold type must be carried out by specialised personnel.
  • Page 44 1. Refill pellet hopper If it is first ignition the fuel, having to go the route that goes from the tank to the brazier, may not be able to arrive on time and in the right amount programmed 2. If after repeated ignitions did not appear in the 1.
  • Page 45 1. Check operation of the sensor and replace 1. Temperature sensor if necessary The air fan convention temperature control defective 2. Check operation of the motor and replace never stops or broken if necessary 2. Fan failure Room thermostat In the automatic 1.
  • Page 46 The thermostove boils under “modulation” 1. It ‘been set to a value of that reaches the thermostat too high 1. Lower the temperature in the boiler temperature set on 2. It was set too much power to 2. Reduce the value of operating power the thermostat of the the implant.
  • Page 47 NOTES...
  • Page 48 Your stove warranty is valid for two years (one year on electrical components) provided it is installed, commissioned and maintained as recommended by the manufacturer. Your first point of contact for warranty issues is your Authorised Kalor Dealer (where you purchased your stove) PLEASE NOTE: Commissioning of your stove MUST be carried out by an Authorised Kalor Technician.

This manual is also suitable for:

Mara

Table of Contents