Kalor Paola 13-13D User Manual page 12

Insert wood pellet stoves
Table of Contents

Advertisement

to the ue pipe, using pipes and connectors as
recommended by us. You must ensure that a
windproof cowl should be tted which complies
with the standards in force.
Fireplace ue gas
Avoid contact with combustible materials
(example: wooden beams) and in any case
provide for their insulation with ame retardant
material. In case of pipe penetrations through
roofs or walls is recommended to use special kits
crossing, certi cates, are available commercially.
In the event of a chimney re, turn off the Insert,
disconnect from the network and never open the
door. Then call the authorities.
The chimney cap
The chimney cap must respect the following
requirements:
• It must have the equivalent diameter and
internal form of the ue.
• It must have a useful outlet diameter of not less
than double that of the ue.
• The chimney cap on the roof or that remains in
contact with the outside (for example, in case
of open lofts or attics), must be covered with
elements in brick or tile and must, in any case,
be well insulated.
• It must be constructed to prevent rain, snow,
and extraneous bodies from entering the ue
and so that the discharge of the products of
combustion is not inhibited by wind from any
quarter or strength (wind-proof chimney cap).
• The chimney cap must be positioned in such
a way as to guarantee the adequate dispersion
and dilution of the products of combustion and
in any case, must be out of the re ux zone.
This zone has different dimensions and forms
according to the angle of inclination of the roof
so it is necessary to adopt minimum heights
• The chimney cap must be a wind-proof type
and must be above the ridge.
• Eventual structures or other obstacles that are
higher than the chimney cap must not be too
close to the chimney cap itself.
82
REMARKS:
- the appliance must be installed by a quali ed
technician in possession of the technical and
professional requirements according to the
DM37/2008 that, under its responsibility, to
ensure compliance with the rules of good
technique.
- the Insert must be connected to a heating
system and/or to a network of production
of sanitary hot water, consistent with its
performance and its power
- you need to keep in mind all laws and national,
regional, provincial and municipal laws of the
country in which you installed the device
- check that the
necessary use a suitable platform
- in the room where the generator must be
installed to heat must not pre-exist or be installed
with an extractor hood or ventilation ducts of the
collective type.
Should these devices be located in adjacent
rooms communicating with the installation, and
'prohibited the simultaneous use of the heat
generator, where there is a risk that one of the
two rooms being placed in depression than the
other
- it is not permissible to install in bedrooms or
bathrooms
YES
Characteristics of chimney
oor is not
ammable: if
NO

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chiara 15-15d

Table of Contents