Kalor Paola 13-13D User Manual page 34

Insert wood pellet stoves
Table of Contents

Advertisement

The stove does
not turn on
automatically
Lock the stove.
Pellets not
being fed into
the combustion
chamber
The stove runs for
a few minutes and
then turn off
Fume extraction
fan does not stop
104
1. The tank is empty.
2. The resistance does not
reach the temperature
3. Resistance damaged
4. The pellet drops
5. Screw motor defective
6. The grate is not in place
or is dirty
7. Obstruction of nests
or foreign bodies in the
chimney or replace
8. Check operation of the
glow plug
9. The ash drawer is not
closed properly
10. Clogged ue and
chimney
11. Smoke extractor not
working
12. Temperature sensor
defective
13. Pellet wet
1. The tank is empty
2. The cochlea is no pellet
3. Technical problem of the
cochlea
4. Reduction motor failure
5. Electronic board faulty
1. Lighting cycle not
completed
2. Temporary failure of
electricity
3. Probes fumes defective
or broken or not inserted
1. The stove has not yet
cooled
1. Fill the tank with pellets
2. Check the electrical wiring and fuses,
replace if the resistance is broken
3. Replace the resistance
4. It is recommended to unplug the power
supply before:
- check that the pellet is not caught in the
chute
- check that the cochlea is not blocked by
dirt
- check the seal of the pellet-door
5. Contact an authorized service center
6. Check that the hole in the brazier
matches the glow plug, clean brazier
7. Remove any foreign body from the
chimney or ue pipe
8. Make sure that there is power. Replace
the spark plug if burned
9. Close the drawer ashtray
10. Perform periodic cleaning
11. Check the operation of the extractor ue
12. Contact an authorized service center
13. Make sure the place of stowage pellet
and replace it with a handful of dry pellets
1. Load the pellets in the tank.
2. Fill the tank and proceed as instructed
before ignition stove
3. IT IS RECOMMENDED to unplug the
power supply before:
- empty the thank and manually free the
auger from obstructions (sawdust)
- release the slide from obstructions
- remove the dust accumulation of pellets in
the bottom of the tank
4. Replace the reduction motor
5. Replace the electronic board
1. Re-run power
2. Re-run power
3. Check and replace sensors
1. Allow the stove to cool. Only after cooling
fan will stop.
If the problem persists, contact your
authorized service center

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chiara 15-15d

Table of Contents