Mandatory microswitch connection
Only for not ducted Inserts
If the Insert is not ducted it is mandatory to
connect the microswitch located behind the
air's front door.
This operation must be done exclusively by
a specialized technician.
The microswitch is equipped with a shoulder
strap that must be connected in series to the
other safety devices as shown below:
1. Disconnect the cables coming from the
microswitch basement
(Foto 1 / 2)
2.
Now connect the microswitch cables of
the air's door to the cables that have just
been disconnected (Foto 3 / 4)
The male of the air door microswitch strap (A)
must be connected to the female that goes to
the electronic board (B). Connect the female of
the strap of the air door microswitch (C) with
the male of the riser coming from the base
microswitch (D).
This connection interrupts the pellet supply when the micro switch door is closed.
This is of fundamental importance because if the door is closed the hot air can not be released
into the room and the replace insert will overheat.
To avoid this, the specialized technician must check that the pellet feed functions should work
only with the Insert fully inserted and with the air ap open.
If the insert is ducted this connection is not necessary.