CLEANING BY THE TECHNICAL
Check every year
Cleaning of combustion chamber and lower compartment
With cold and inactive insert proceed as follows:
Open the door and remove
the brazier.
Use
a
vacuum
to clean the walls of the
combustion chamber. Use
a tool to clean the exchange
pipes by removing all the
combustion residues.
100
1
Push the back plate up.
4
cleaner
Once
chamber has been cleaned,
remove the ash drawer.
2
5
the
combustion
Rotate the plate towards the
front of the insert.
To reposition the back plate,
lightly
press
the
partition until the back plate
is completely inserted.
3
6
upper