Kalor Paola 13-13D User Manual page 36

Insert wood pellet stoves
Table of Contents

Advertisement

The re goes out
or the stove stops
automatically
The air fan
convention
(ambient air) never
stops
The stove does
not light.
The manufacturer of the stove any liability and will void the warranty terms of
the product for any inconvenience caused by not following the rules described
above. Any work of service center will be borne by the applicant if they are not
complied with these instructions.
106
1. The pellet tank is empty
2. No power
3. Pellets not being fed
4. Excessive deposit of
ashes in the grate
5. Intervention probe
temperature safety of the
pellet
6. Cochlea blocked by dirt
7. The door is not closed
properly or gaskets worn
8. Pellet inadequate
9. Low pellet
10. Chimney or drain
clogged with nests or
foreign bodies
11. Pressure switch cuts
12. Smoke extraction motor
failure
13. Alarm active
1. Temperature sensor
temperature control
defective or broken
2. Smoke probe fails
1. Lack of electricity
2. Probe pellets in bulk
3. Fuse blown
4. Pressure switch broken
(lockout indicated)
5. Smoke outlet or duct
clogged
1. Fill the tank with pellets
2. Check plug and presence electricity
3. Fill the tank with pellets
4. Clean the brazier
5. Let the stove cool down completely,
reset the manual reset and restart the stove.
If the problem persists, contact your
authorized service representative
6. Pull the plug, empty the tank, remove any
foreign objects
7. Close the door or replace the gaskets
with original
8. Change the type of pellet recommended
by the manufacturer.
Sometimes, depending on the type, the
stage of adjustment of the parameters
need to vary the level relating to the
loading of pellets
9. Increase the level in the parameter for the
pellet feed. To check the ow of fuel from
technical authorized
10. Eliminate all foreign matter from the
chimney Clean the smoke duct. Perform
periodic cleaning.
11. Verify potential smoke duct is
blocked and if the pressure switch is
working properly
12. Check and replace the motor if
necessary
13. See paragraph alarms
1. Check the operation of the sensor and
replace if necessary
2. Replace smoke probe
1. Check that the electrical outlet is plugged
in and the power switch to "I"
2. Lockout by resetting the rear thermostat,
replace the thermostat if it happens again
3. Replace the fuse
4. Replace the pressure
5. Clean the smoke outlet and / or smoke
duct