Kalor Paola 13-13D User Manual page 35

Insert wood pellet stoves
Table of Contents

Advertisement

The stove is
clogged early in
the brazier with
burning irregular,
door glass gets
dirty, the ame is
long, reddish and
weak
Smell of smoke in
the environment.
Turning off the
stove.
In the automatic
position the stove
always runs at full
power
The engine smoke
extraction does
not work
1. Flue with presence
of stretches too long or
clogged
2. Too pellet
3. Excessive pellet or ash
deposits in the brazier
4. The brazier is not found
in its slot
5. Wind contrary to the
exhaust ow
6. Insuf cient combustion
air
7. You changed the type of
pellets used
8. Smoke extractor motor
broken
9. Door closed incorrectly
1. Poor combustion
2. Malfunction of fan fumes
3. Installation of the ue
performed incorrectly
4. Clogged chimney
1. Room thermostat set to
maximum
2. Signi cant temperature
sensor failure
3. Control panel defective
or broken
1. The stove has no voltage
2. The motor is broken
3. The board is defective
4. The control panel has
failed
1. Perform periodic cleaning. See paragraph
stove installation in the user manual. Check
chimney cleaning
2. Decrease in the parameters the charge
level of the pellets
3. Clean the brazier after waiting for the
total shutdown of the stove. If you repeat
contact your Authorized Service Center
4. Check that the hole in the brazier
matches the glow plug
5. Check the chimney cap windproof and /
or possibly install it
6. Check the correct position of the brazier,
its cleanliness and check that the air intake
in both free environment, verify the status
of the door seal, increase the level in the
parameter relative to the speed of the fan
exhaust fumes. Contact your Authorized
Service Center
7. Check the quality of the pellets. Contact
your Authorized Service Center
8. Increase the level in the parameters
relating to the speed of the fan exhaust
fumes. Check and eventually replace motor
9. Check that the glass is sealed and the
seal guarantees tightness
Contact your Authorized Service Center
1. Reset the thermostat temperature
2. Check the operation of the sensor and
replace if necessary
3. Check the control panel and replace if
necessary
1. Check the supply voltage and the
protection fuse.
2. Check the motor and capacitor and
replace if necessary.
3. Replace the circuit board.
4. Replace the control panel.
105