7.1 Alarm signals

In the event of a working defect, the system informs the user about the type of failure occurred. The following table summarises
the alarms, kind of problem and possible solution:
Display
ALAR 1
BLACK OUT
PROBE
ALAR 2
EXHAUST
HOT
ALAR 3
EXHAUST
FAN
ALAR 4
FAILURE
ALAR 5
LIGHTIN
ALAR 6
PELLET
SAFETY
ALAR 7
THERMAL
FAILURE
ALAR 8
DEPRESS
SERV
Regular checks should be carried out by the user, who should only contact the Authorized
Assistance Center if no solution is found.
Kind of problem
There is no power supply
The smokes sensor is broken or not
connected to the pcb
Smokes temperature too high
Smokes extractor blocked or broken
NO
The Insert cannot start up
This is the first light-up
NO
The pellet Insert switched off while
working
The water temperature exceeds 100°C.
Obstructed flue
The Insert has worked for 1200 hours.
Supplementary maintenance required
Solution
As soon as the power supply is back, the Insert
starts a cooling cycle: it will be necessary to
restart it manually
Contact an Authorized Assistance Center
Switch off the Insert, allow it to cool down
and perform ordinary cleaning. If the problem
persists, contact an Authorized Assistance Center
for cleaning the Insert and the flue
Contact an Authorized Assistance Center
Fill in the tank with pellets
Start up again
Fill in the tank with pellets
Clean the inert and the flue. Reset the thermost
manually. If the problem persists, contact an
Authorized Assistance Center
Clean the flue or check there are no obstructed
grids near the smokes exhaust
Contact an Authorized Assistance Center