Operating area

It is not permissible to install the
Insert in bedrooms, bathrooms, or
in a room where another heating
appliance
Insert etc.) which does not have its own
independent air intake. Locating the Insert
in a room with an explosive atmosphere
is prohibited. The oor of the room where
the Insert is to be installed must be strong
enough to take its weight. Keep a minimum
distance of 5 cm between the covering and
the replace insert. If walls are ammable,
maintain a minimum distance of 20 cm at
the rear , of 40 cm at the side and 100 cm
at the front. If the room contains objects
which are believed to be particularly
delicate, such as drapes, sofas and other
furniture, their distance from the Insert
should be considerably increased. The two
side walls of the chimney insert must be
accessible for maintenance by authorized
technicians.
How to place the Insert
For proper functioning and a good temperature
distribution, the Insert shoul be positioned
in a location where it is able to take in the air
necessary for combustion of the pellet (about
40 m
/h must be available), as laid down in
3
the standard governing the installation and in
accordance with local national standards.
The volume of the room must not be less than
30 m
.
3
The air must come in through permanent
openings made in walls (in proximity to the Insert)
which give onto the outside, with a minimum
cross-section area of 100 cm
These openings must be made in such a way
that it is not possible for then to be obstructed
in any way. Alternatively, the air can be taken
from rooms adjacent to the one which needs
ventilating, as long as they are provided with
an air intake from the outside, and are not used
as bedrooms or bathrooms, and provided there
is no re risk such as there is for example in
garages, woodsheds, and storerooms, with
particular reference to what is laid down in
current standards.
80
is
installed
(Insert,
.
2
Distances to consider for the installation of stoves,
thermo-stoves, hydro and air inserts.
Connection to the external air intake
It is essential that at least as much air must be
able to ow into the room where the Insert is
installed as is required for proper combustion in
the appliance and for the ventilation of the room.
This can be effected by means of permanent
openings in the walls of the room to be ventilated,
which give onto the outside, or by single or
collective ventilation ducts.
For this purpose, on the external wall near the
Insert, a hole must be made with a minimum free
cross-section of 100 cm
hole of 12 cm diameter or a square hole 10x10
cm) protected by a grille on the inside and the
outside.
The air intake must also: communicate directly
with the room where the Insert is installed be
protected by a grille, metal mesh or suitable
guard, as long as this does not reduce the area
below the minimum.
Be positioned in such a way as to be impossible
to obstruct.
Min.
100 cm
2
. (equivalent to a round
2