Problems and solutions

All repairs must be carried out exclusively by a specialised technician, with the
stove completely cold and the electric plug pulled out. Is prohibited from any
unauthorized modi cation to the device and the replacement of parts with other
non-original. The operations marked in bold type must be carried out by specia-
lised personnel.
Any inconvenience and solutions
Given that all stoves are tested in their parts handling and work and therefore are delivered in
perfect physical condition and operation, it should be remembered that the transport, unloading,
handling, misuse or poor maintenance, can be causes of drawbacks. The main problems may be
solved by reading the table below. If after doing as hereinafter described the problem is not re-
solved, contact your authorized service center.
PROBLEM
Display off and
buttons are not
working
Remote inef cient
Failure to ignite
the stove
Smoke comes
from the grill
Hot air fan is not
working
POSSIBLE CAUSE
1. Power failure in the net-
work
2. Switch back off
3. Display defective
4. Fault in the connection of
the display with the card
5. Fuse board interrupted
6. Card defective
1. Too far from the stove
2. No batteries in the re-
mote
3. The remote control is
broken
1. Excessive accumulation
of ash in the grate
2. Incorrect ignition proce-
dure
1. Accidental electrical
blackout
1. The stove has not yet
been heated
REMEDY
1. Check that the power cord is connected
2. Use the switch back to operate it
3. Unplug the stove from the power outlet
for about one minute and then turn on. If
the problem persists, contact an authorized
service center
4. Check that the display and board are
properly connected. Contact your author-
ized service center
5. Contact an authorized service center
6. Contact an authorized service center
1. Move closer to the stove
2. Check and change the batteries
3. Replace the remote control
1. Clean the grate
2. Repeat the ignition procedure. If
the problem persists, contact your
authorized service center
1. In case of ignition phase interrupted
and momentary interruption of the fan, can
occur slight amount of smoke
1. Wait until the conclusion of the ignition
cycle.
Arrived in temperature, the fan will start
automatically. If the problem persists,
contact your authorized service center.