Mounting on a bypass / bridle
SLG 700 transmitter can be successfully installed in a new or existing bypass pipe,
bridle, or a side pipe as shown Figure 3-36: Bypass installation. This type of installation
is often simpler and allows the addition of radar level measurement to an otherwise busy
installation.
A similar installation is also possible inside the main container, when installing the SLG
700 transmitter on a stilling well.
N = Inlet diameter
L = Effective measurement range (≥ 12"/300mm)
D = Bypass diameter (N<D)
Table 3-18: SLG720 bypass and stillwell recommended diameters
Probe type
Rod probe
Wire probe
Page 82
Figure 3-36: Bypass installation
Recommended diameter
3" or 4" (75mm or 100mm)
4" (100mm)
SLG 700 SmartLine Level Transmitter User's Manual
Minimum diameter
2" (50mm)
2" (50mm)
Revision 8