Combined Power Supply
®
2N
IP Base
can be fed from an external power supply and PoE at the same time.
LAN Connection
®
2N
IP Base
is connected to the Local Area Network (LAN) via the UTP/STP cable
(Cat 5e or higher) terminated with an RJ-45 (LAN) connector. As the device is
equipped with the Auto-MDIX function, both the straight and crossed cable can be
used.
Caution
We recommend the use of a LAN surge protection.
We recommend the use of a shielded SSTP Ethernet cable.
Reset Button
Located among the main unit connectors, the Reset button helps you reset the factory
default values, restart the device, find the device IP address and switch the static
/dynamic mode.
Factory Reset
Follow the instructions below to
Press and hold the RESET button.
Wait until the red and green LEDs on the device come on simultaneously
(approx. 20 s).
Wait until the red LED goes off (approx. 5 s).
Wait until the green LED goes off and the red LED comes on again (approx. 5 s).
Wait until the red LED goes off (another 5 s).
Release the RESET button.
2N TELEKOMUNIKACE a.s., www.2n.cz
reset the factory default values
:
36/66