Specifications
8.7.1 CE Compliance
200–240 V
Enclosure
A1
A2
A3
A4
A5
B1
B2
8
8
B3
B4
C1
C2
C3
C4
Table 8.13 200–240 V, Enclosure Types A, B and C
70
Power (hp [kW])
Recommended
fuse size
0.34–2 [0.25–1.5]
gG-10
0.34–3 [0.25–2.2]
gG-10 (0.25–1.5)
gG-16 (2.2)
4–5 [3.0–3.7]
gG-16 (4 [3])
gG-20 (5 [3.7])
0.34–3 [0.25–2.2]
gG-10 (0.25–1.5)
gG-16 (2.2)
0.34–5 [0.25–3.7]
gG-10 (0.34–2 [0.25–1.5])
gG-16 (3–4 [2.2–3])
gG-20 (5 [3.7])
7.5–10 [5.5–7.5]
gG-25 (5.5)
gG-32 (7.5)
15 [11]
gG-50
7.5 [5.5]
gG-25
10–20 [7.5-15]
gG-32 (7.5)
gG-50 (11)
gG-63 (15)
20–30 [15–22]
gG-63 (15)
gG-80 (18.5)
gG-100 (22)
40–50 [30–37]
aR-160 (30)
aR-200 (37)
25–30 [18.5–22]
gG-80 (18.5)
aR-125 (22)
40–50 [30–37]
aR-160 (30)
aR-200 (37)
Danfoss A/S © Rev. 09/2014 All rights reserved.
Instruction Manual
Recommended
maximum fuse
gG-25
gG-25
gG-32
gG-32
gG-32
gG-80
gG-100
gG-63
gG-125
gG-160 (15–18.5)
aR-160 (22)
aR-200 (30)
aR-250 (37)
gG-150 (18.5)
aR-160 (22)
aR-200 (30)
aR-250 (37)
Recommended circuit
Maximum trip level
breaker Moeller
PKZM0-16
PKZM0-25
PKZM0-25
PKZM0-25
PKZM0-25
PKZM4-63
NZMB1-A100
PKZM4-50
NZMB1-A100
NZMB2-A200
NZMB2-A250
NZMB2-A200
NZMB2-A250
[A]
16
25
25
25
25
63
100
50
100
160
250
150
250