Danfoss VLT AutomationDrive FC 301 Instruction Manual page 39

0.25–75 kw
Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Application Set-up Examples
Table 6.13 Using SLC to Set a Relay
6.1.8 Mechanical Brake Control
FC
+24 V
12
+24 V
13
D IN
18
D IN
19
COM
20
D IN
27
29
D IN
D IN
32
D IN
33
D IN
37
+10 V
50
A IN
53
A IN
54
COM
55
A OUT
42
COM
39
01
02
03
04
05
06
Table 6.14 Mechanical Brake Control
MG33AP22
Instruction Manual
Parameters
Notes/comments:
If the limit in the feedback
monitor is exceeded, Warning
90 is issued. The SLC monitors
Warning 90 and if Warning 90
becomes TRUE, Relay 1 is
triggered.
External equipment may then
indicate that service may be
required. If the feedback error
goes below the limit again
within 5 s, the adjustable
frequency drive continues and
the warning disappears. But
Relay 1 is still triggered until
[Reset] on the LCP.
Parameters
Function
Setting
5-40 Function
[32] Mech.
Relay
brake ctrl.
5-10 Terminal 18
[8] Start*
Digital Input
5-11 Terminal 19
[11] Start
Digital Input
reversing
1-71 Start Delay
0.2
1-72 Start
[5] VVC
+
/
Function
FLUX
Clockwise
1-76 Start
I
m,n
Current
2-20 Release
App.
Brake Current
dependent
2-21 Activate
Half of
Brake Speed
nominal slip
[RPM]
of the motor
*=Default Value
Notes/comments:
Danfoss A/S © Rev. 09/2014 All rights reserved.
1-76
Current
Speed
1-71
2-21
Start (18)
Start
reversing (19)
Relay output
Open
Closed
Figure 6.4 Mechanical Brake Control
Time
1-71
2-21
37
6
6