Specifications
Type designation
1)
High/Normal overload
Typical shaft output at 550 V (hp [kW])
Typical Shaft output at 690 V (hp [kW])
Enclosure protection rating IP20
Enclosure protection rating IP21, IP55
Output current
Continuous (525–550 V) [A]
Intermittent (60 s overload) (525–550 V)
[A]
Continuous (551–690 V) [A]
Intermittent (60 s overload) (551–690 V)
[A]
continuous KVA (at 550 V) [KVA]
continuous KVA (at 690 V) [KVA]
Maximum input current
Continuous (at 550 V) [A]
Intermittent (60 s overload) (at 550 V) [A]
Continuous (at 690 V) [A]
Intermittent (60 s overload) (at 690 V) [A]
Additional specifications
Maximum cable cross-section for line
2
power and motor [mm
] ([AWG])
Maximum cable cross-section for load
2
share and brake [mm
] ([AWG])
2)
Maximum cable cross-section
for line
2
power disconnect [mm
] ([AWG])
Estimated power loss
at rated maximum load (hp [W])
4)
Efficiency
Table 8.12 B4, C2, C3 Enclosure, Line Power Supply 525–690 V IP20/IP21/IP55 - Chassis/NEMA1/NEMA 12 (FC 302 only), P30K-P75K
For fuse ratings, see chapter 8.7 Fuses and Circuit Breakers.
1) High overload=150% or 160% torque for a duration of 60 s. Normal overload=110% torque for a duration of 60 s.
2) The three values for the maximum cable cross-section are for single core, flexible wire and flexible wire with sleeve, respectively.
3) Applies for dimensioning of adjustable frequency drive cooling. If the switching frequency is higher than the default setting, the power losses
may increase. LCP and typical control card power consumptions are included. For power loss data according to EN 50598-2, refer to
www.danfoss.com/vltenergyefficiency
4) Efficiency measured at nominal current. For energy efficiency class, see chapter 8.4 Ambient Conditions. For part load losses, see
www.danfoss.com/vltenergyefficiency.
MG33AP22
Instruction Manual
P30K
HO
NO
30 [22]
40 [30] 40 [30]
40 [30]
50 [37] 50 [37]
B4
C2
36.0
43.0
54.0
47.3
34.0
41.0
51.0
45.1
34.3
41.0
40.6
49.0
36.0
49.0
54.0
53.9
36.0
48.0
54.0
52.8
0.805
0.992
0.992
3)
[600]
[740]
[740]
0.98
Danfoss A/S © Rev. 09/2014 All rights reserved.
P37K
P45K
HO
NO
HO
NO
50 [37]
50 [37]
60 [45]
60 [45]
60 [45]
75 [55]
C3
C3
C2
C2
43.0
54.0
54.0
65.0
64.5
59.4
81.0
71.5
41.0
52.0
52.0
62.0
61.5
57.2
78.0
68.2
41.0
51.4
51.4
61.9
49.0
62.1
62.1
74.1
49.0
59.0
59.0
71.0
72.0
64.9
87.0
78.1
48.0
58.0
58.0
70.0
72.0
63.8
87.0
77.0
150 (300 MCM)
95 (3/0)
95, 70, 70
(3/0, 2/0, 2/0)
1.207
1.207
1.475
[900]
[900]
[1100]
0.98
0.98
P55K
P75K
HO
NO
HO
NO
60 [45]
75 [55]
65 [50] 100 [75]
75 [55] 100 [75] 100 [75] 125 [90]
D3h
D3h
C2
C2
65.0
87.0
87.0
105
97.5
95.7
130.5
115.5
62.0
83.0
83.0
100
93.0
91.3
124.5
110
61.9
82.9
82.9
100
74.1
99.2
99.2
119.5
71.0
87.0
87.0
99.0
105.0
95.7
129
108.9
70.0
86.0
-
-
105
94.6
-
-
185, 150, 120
(350 MCM,
-
300 MCM, 4/0)
1.475
2.012
2.012
2.414
[1100]
[1500]
[1500]
[1800]
0.98
0.98
8
8
63