Configuration Option Tables
Copy Ports Options
Î
A-6
You can copy the configuration options of DSX-1 interface and DSL loop to
another using the Copy Ports screen. For Copy Ports options, refer to Table A-3.
To access the Copy Ports screen, follow this menu selection sequence:
Main Menu
Configuration
main/config/copy
Slot 4
Perform Copy
Perform Copy Then Increment
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Save
Table A-3. Copy Ports Options
From: Port n
Possible Settings: 1, 2, 3, 4
Default Setting: 1
Controls the source of the configuration options.
1 to 4 – The configuration of the selected port is copied.
To: Port y
Possible Settings: 1, 2, 3, 4, All
Default Setting: 2
Controls the target of the configuration options.
1 to 4 – The configuration of the selected port is replaced. If Perform Copy Then
Increment is selected, the port number is incremented by 1 after the copy.
All – The configurations of all ports are replaced by the configuration of the selected
From: Port.
Peer IP Address and Circuit Identifier are not copied.
NOTE:
December 1998
Load Configuration From
COPY PORTS
From: Port n :
To:
Port y :
ESC for previous menu
Copy Ports
Hotwire
Model: 8774
Î Î
MainMenu Exit
8774-A2-GB20-10