Monitoring the 8774 Termination Unit
4-4
Table 4-1. Health and Status Messages (2 of 2)
Message
What Message Indicates
EER at DSX-1,
An EER (Excessive Error
Pt n
Rate) condition has been
detected on the DSX-1
interface.
Yellow alarm at
A Yellow Alarm Indication
DSX-1, Pt n
signal is being received by
the DSX-1 interface.
Net Margin
The signal-to-noise margin
Threshold, Pt n
has exceeded the configured
threshold.
Primary Clock
A failure has occurred in the
Failed (DSX-1,
primary clock source
Pt n )
configured from the Network,
DSX, or from the card internal
clock.
Device Failed
An internal error has been
yyyyyyyy
detected by the operating
software. yyyyyyyy indicates
the 8-digit hexadecimal failure
code.
Download Failed
A firmware download was
interrupted.
Net Com Link
The Network communication
Down
link is down. Communications
between the management
system and the LTU/NTU is
not possible.
December 1998
What To Do
1. Verify the attached equipment
coding is compatible.
2. Contact network provider.
1. Verify that the units line framing
and line coding are compatible.
2. Contact network provider.
1. Reconfigure the unit to a higher
Net Margin Threshold.
2. Contact network provider.
1. Verify that the network cable is
securely attached at both ends.
2. Contact network provider.
1. Provide the 8-digit failure code
shown ( yyyyyyyy ) to your service
representative.
2. Reset the 8774 Termination Unit
to clear the condition and
message.
Repeat the download.
1. Verify that the network cable is
securely attached at both ends.
2. Verify the link protocol for the
COM port is configured correctly.
8774-A2-GB20-10