8774-A2-GB20-10
Table A-6. SNMP Traps Options (3 of 3)
Link Traps
Possible Settings: Disable, Up, Down, Both
Default Setting: Both
Determines if SNMP traps are generated for link up and link down for one of the
communication interfaces.
Disable – No linkUp or linkDown SNMP traps are generated.
Up – A linkUp trap is generated when the 8774 Termination Unit recognizes that one of
the communication interfaces is operational.
Down – A linkDown trap is generated when the 8774 Termination Unit recognizes a
failure in one of the communication interfaces.
Both – Sends trap messages for detection of both linkUp and linkDown .
NOTE:
Refer to
linkUp and linkDown
SNMP Traps .
Link Trap Interfaces
Possible Settings: Network, DSX-1, All
Default Setting: All
Determines if the SNMP linkUp , SNMP linkDown , and interface-related
enterpriseSpecific traps are generated for the network DSL interface and/or DSX-1
interface (DTE).
Network – SNMP trap messages are generated for the DSL network interface.
DSX-1 – SNMP trap messages are generated for the DSX-1 interface.
All – SNMP trap messages are generated for the DSL network interface and the DSX-1
interface.