Paradyne Hotwire 8774 User Manual page 89

M/sdsl termination unit with dsx-1 interface
Hide thumbs Also See for Hotwire 8774:
Table of Contents

Advertisement

Configuration Option Tables
Table A-7. General SNMP Management Options (2 of 2)
Name 1 Access
Possible Settings: Read, Read/Write
Default Setting: Read
Determines the access level for Community Name 1.
Read – Allows read-only access (get) for Community Name 1.
Read/Write – Allows read/write access (get) for Community Name 1.
Community Name 2
Possible Settings: ASCII text field, Public
Default Text: Public
Identifies the name of the second community allowed to access the unit's MIB. The
community name must be supplied by an external SNMP manager when that manager
attempts to access an object in the MIB.
Text Field – Enter or edit a community name.
Clear – Clears the community name field.
Name 2 Access
Possible Settings: Read, Read/Write
Default Setting: Read
Determines the access level for Community Name 2.
Read – Allows read-only access (get) for Community Name 2.
Read/Write – Allows read/write access (get/set) for Community Name 2.
8774-A2-GB20-10
December 1998
A-15