Installing Cellular/Ethernet Communicator in
Figure 3:Communicator Wiring Diagram
Input Ratings from Bell +:
+11.1V ~ +12.6 VDC
100mA standby; 400mA alarm
DSC Panel min. power requirements:
- 16 VAC 40 VA transformer;
- 12 VDC 7Ah battery
PC1616/1832/1864
Do NOT
connect
Red or Black
Keybus wires!
Keybus Connection
4. Install the Keybus cable between Communicator and Panel as follows:
WARNING
: D
O
THE
a. Attach a wire from the Communicator YEL terminal to the panel YEL terminal.
b. Attach a wire from the Communicator GRN terminal to the panel GRN terminal.
Install Network Cable (TL2603G/TL260 only)
5. Route the CAT 5 Ethernet cable through back of the panel and plug it into the Communicator's
RJ45 jack.
NOTE: Before leaving the premises the Ethernet communication lines must first be connected to
an approved (acceptable to local authorities) type NID. All wiring shall be performed according to
the local electrical codes.
6. Perform the following steps for initial power on of the panel with Communicator installed:
a. Reconnect the AC power, telephone line, and battery + connector to the panel.
(The Communicator and Panel will power up together).
b. Observe that the Communicator's red and yellow LEDs are flashing together while it initial-
izes. The red and yellow LEDs will continue to flash until the Communicator has success-
fully communicated to all programmed receivers.
NOTE: Initialization may take several minutes to complete. red and yellow LEDs will flash
together during initialization. Do not continue to next step until the red and yellow LEDs have
stopped flashing. (If only the yellow LED is flashing, there is a Communicator trouble and the
Green LEDs are not valid for Communicator Placement Test). Correct trouble indicated by flashes
on yellow LED before continuing. (See Table 9 for troubleshooting assistance).
7. Perform the Communicator Placement Test below.
8. Mount the Panel in final location indicated by placement test.
UA503
XX
AC AC
AUX+
PGM1
PGM3
PGM2
PGM4
NOT
K
CONNECT
EYBUS
C
T
OMMUNICATOR
ERMINAL
3G Alarm Communicator Installation Manual
To external antenna
L
SIM
o
c
k
DSC
UA601
Black
1
PC-LINK
Z1 COM Z2 Z3 COM Z4 Z5 COM
Z6 Z7 COM Z8
RING
Yellow
Green
R
B
ED OR
LK WIRES TO THE
B
.
LOCKS
7
1
AUDIO/DEFAULT
Jumper pins 4 and 5
3G Radio
to reset.
TL2603G(R)
Network Link
TL260(R)
YELLOW
3G2060(R)
RJ-45
PC-LINK
COM
Black
Maximum cable length
100 m (328 ft)
TIP
T-1
R-1
+
+
-
-
External Bell/Siren
P
ANEL OR
From NID
TL2603G(R)
Use only CAT5
Supervised