DSC 3G2060 Installation Manual page 22

Internet/hspa alarm communicator
Table of Contents

Advertisement

Ethernet/Cellular Programming Options
[025] Radio Activation Restore
Default (FF)
Program 00 to disable this event or FF to enable. This event will occur after any successful Con-
nect24 programming session.
System Test Options [026 - 029]
Test Transmissions to Primary Receiver, with Backup to Secondary Receiver:
Set Ethernet Section [026] to (FF); [027] to (00). Set Cellular Section [028] to (FF); [029] to (00).
• If the test transmission fails to the primary receiver it will backup to the secondary receiver.
• If the test transmission fails to the secondary receiver an FTC trouble will be generated.
Test Transmission Unique to Primary and Secondary Receivers:
Set Ethernet Section [026] to (FF); [027] to (FF). Set Cellular Section [028] to (FF); [029] to (FF).
• The module will send periodic test transmissions to each receiver independently, with no back-
ups.
• If the test transmission fails to any of the programmed receivers, an FTC trouble will be gener-
ated.
Alternate Test Transmission:
Alternate Test Transmission can be enabled or disabled in Section [005] Toggle Option [7].
Alternate Test Transmission with backup receivers:
Set Ethernet Section [026] to (FF); [027] to (00). Set Cellular Section [028] to (FF); [029] to (00).
Interval 1:
• If the test transmission fails to the primary receiver it will backup to the secondary receiver.
• If the test transmission fails to the secondary receiver an FTC trouble will be generated.
Interval 2:
• If the test transmission fails to the secondary receiver it will backup to the primary receiver.
• If the test transmission fails to the primary receiver an FTC trouble will be generated.
Test Transmission Unique to Primary and Secondary Receivers:
Set Ethernet Section [026] to (FF); [027] to (FF). Set Cellular Section [028] to (FF); [029] to (FF).
Interval 1:
• The module will send periodic test transmissions to Primary receivers (Ethernet Primary and
Cellular Primary) independently, with no backups.
• If the test transmission fails to any of the programmed primary receivers, an FTC trouble will
be generated
Interval 2:
The module will send periodic test transmissions to Secondary receivers (Ethernet Secondary and
Cellular Secondary) independently, with no backups.
• If the test transmission fails to any of the programmed secondary receivers, an FTC trouble will
be generated
[026] Ethernet 1 Transmission
Default (FF)
Program 00 to disable this event transmission or FF to enable. See System Test Options (above)
for details on settings.
[027] Ethernet 2 Transmission
Default (00)
Program 00 to disable this event transmission or FF to enable. See System Test Options (above)
for details on settings.
[028] Cellular 1 Transmission
Default (FF)
Program 00 to disable this event transmission or FF to enable. See System Test Options (above)
for details on settings.
3G Alarm Communicator Installation Manual
18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tl2603gTl260

Table of Contents