PNU
Description
P592
Source for actual value of "n < n comp. signal"
*
n < n comp. signal:
Selection of connector to be injected as input quantity (n) for the n < n comp.
(G187)
signal.
0 = connector K0000
1 = connector K0001
etc.
P593
Source for actual value of "n < n min signal"
*
n < n min signal:
Selection of connector to be injected as input quantity (n) for the n < n min
(G187)
signal.
0 = connector K0000
1 = connector K0001
etc.
P594
Source for input quantity of "Polarity signal"
*
Polarity signal of speed setpoint:
Selection of connector to be injected as input quantity "n set " for the polarity
(G188)
signal of the speed setpoint.
0 = connector K0000
1 = connector K0001
etc.
P595
Source for actual value of "Overspeed signal"
*
Overspeed signal:
Selection of connector to be injected as input quantity "n act " for the
(G188)
overspeed signal.
0 = connector K0000
1 = connector K0001
etc.
P596
Source for setpoint of "nset = nact signal 2"
*
Setpoint/actual value deviation signal:
Selection of connector to be injected as input quantity "n set " for the
(G187)
setpoint/actual value deviation signal.
0 = connector K0000
1 = connector K0001
etc.
P597
Source for actual value of "nset = nact signal 2"
*
Setpoint/actual value deviation signal:
Selection of connector to be injected as input quantity "n act " for the
(G187)
setpoint/actual value deviation signal.
0 = connector K0000
1 = connector K0001
etc.

10.34 Configuring of closed-loop control

Setting values for configuring of torque shell
P600
Source for gating unit input (armature)
*
i001 to i004:
(G163)
Selects which connectors are applied as the gating unit input
(armature). All four values are added.
Settings:
0 = connector K0000
1 = connector K0001
etc.
SIEMENS Energy & Automation
SIMOREG DC Master Base Drive Panel Operating Instructions
Value range
[Unit]
Steps
All connector
numbers
1
All connector
numbers
1
All connector
numbers
1
All connector
numbers
1
[SW 1.9 and later]
All connector
numbers
1
[SW 1.9 and later]
All connector
numbers
1
All connector
numbers
1
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: None
P052 = 3
FS=167
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=167
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=170
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=167
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=174
P051 = 40
Type: L2
off-line
Ind: None
P052 = 3
FS=167
P051 = 40
Type: L2
off-line
Ind: 4
P052 = 3
FS=
P051 = 40
i001: 102
off-line
i002: 0
i003: 0
i004: 0
Typ: L2
10-59