Fixed Control Bits; Digital Setpoint Inputs - Siemens 6RA70 Series Instructions Manual

Microprocessor-based converters from 15a to 1680a for variable speed dc drives.
Hide thumbs

Advertisement

PNU
Description
P411
K411 fixed value
FDS
is applied to connector K0411
(G120)
P412
K412 fixed value
FDS
is applied to connector K0412
(G120)
P413
K413 fixed value
FDS
is applied to connector K0413
(G120)
P414
K414 fixed value
FDS
is applied to connector K0414
(G120)
P415
K415 fixed value
FDS
is applied to connector K0415
(G120)
P416
K416 fixed value
FDS
is applied to connector K0416
(G120)

10.20 Fixed control bits

Function:
The value set in the parameter is applied to the specified binector
P421
B421 fixed bit
FDS
is applied to binector B0421
(G120)
P422
B422 fixed bit
FDS
is applied to binector B0422
(G120)
P423
B423 fixed bit
FDS
is applied to binector B0423
(G120)
P424
B424 fixed bit
FDS
is applied to binector B0424
(G120)
P425
B425 fixed bit
FDS
is applied to binector B0425
(G120)
P426
B426 fixed bit
FDS
is applied to binector B0426
(G120)
P427
B427 fixed bit
FDS
is applied to binector B0427
(G120)
P428
B428 fixed bit
FDS
is applied to binector B0428
(G120)
10.21 Digital setpoint input (fixed setpoint, inching and crawling setpoints)
(see also Section 8, Sheets G127, G129 and G130 of Operating Instructions 6RX1700-0AD**)
Fixed setpoint
Function: Up to 8 connectors can be selected in P431 indices .01 to .08. These can be applied as an additional fixed setpoint (K0204,
K0209) via the binectors selected in P430, indices .01 to .08 (setpoint is applied when binector switches to log. "1" state). P432
indices .01 to .08 can be set to define for each setpoint individually whether the ramp-function generator must be bypassed on
setpoint injection.
If fixed setpoint injection is not selected, the connector set in P433 is applied to K0209.
P430
Source for fixed-setpoint injection
*
Selection of binector to control injection of the fixed setpoint
("1" state = fixed setpoint injected).
(G127)
0 = binector B0000
1 = binector B0001
etc.
10-46
Value range
[Unit]
Steps
-199.99 to 199.99
[%]
0.01%
-32768 to 32767
1
-32768 to 32767
1
-32768 to 32767
1
-32768 to 32767
1
-32768 to 32767
1
0 to 1
1
0 to 1
1
0 to 1
1
0 to 1
1
0 to 1
1
0 to 1
1
0 to 1
1
0 to 1
1
All binector numbers
1
SIEMENS Energy & Automation
SIMOREG DC Master Base Drive Panel Operating Instructions
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 4
P052 = 3
FS=0.00
P051 = 40
Type: I2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: I2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: I2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: I2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: I2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: I2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: 8
P052 = 3
FS=0
P051 = 40
Type: L2
Offline

Advertisement

   Also See for Siemens 6RA70 Series

   Related Manuals for Siemens 6RA70 Series

Comments to this Manuals

Symbols: 0
Latest comments:
  • Rolando Guevarra Jan 02, 2018 12:48:
    Hi, i have trouble in our drive, F019, anyone can help to solve this fault. Thanks in advance
  • vivek Kumar Jul 28, 2015 05:25:
    6ra70 drive 250 kw problem field weakning optimizati​on failed fault f050 fault valu 10 plz help... m
  • vk jadaun Jul 18, 2015 02:16:
    242 kw dc drive but problem optimizati​on fail 25 current and field fault F050 fault valu 3.... ... plz suggest...