Ramp-Function Generator Parameter Set 1 (See Also Parameter P330); Ramp-Function Generator Parameter Set 2 (See Also Parameter P330); Ramp-Function Generator Parameter Set 3 (See Also Parameter P330); P302 Select Ramp-Function Generator / Ramp-Up Integrator Mode - Siemens 6RA70 Series Instructions Manual

Microprocessor-based converters from 15a to 1680a for variable speed dc drives
Hide thumbs Also See for 6RA70 Series:
  • Faq (4 pages)
Table of Contents

Advertisement

PNU
Description
Limitation at ramp-function generator output (setpoint limiting)
The effective limitations are:
Upper limit:
Minimum value of P300 and the four connectors selected with P632
Lower limit:
Maximum value of P301 and the four connectors selected with P633
Note:
The limiting values for both the positive and negative setpoint limits can have a positive or negative sign. The negative
setpoint limit, for example, can therefore be parameterized to a positive value and the positive setpoint limit to a negative
value.
P300
Positive limitation at ramp-function generator output
FDS
(G137)
P301
Negative limitation at ramp-function generator output
FDS
(G137)
P302
Select ramp-function generator / ramp-up integrator mode
*
0
Normal ramp-function generator operation:
FDS
Ramp-function generator setting 1 (P303 to P306) is applied.
When a binary selectable input parameterized as "Ramp-
(G136)
function generator setting 2" (P307 to P310)" (selected in P637)
or "Ramp-function generator setting 3" (P311 to P314)"
(selected in P638), generator setting 2 or 3 is applied as
appropriate.
1
Ramp-up integrator operation:
When the setpoint is reached for the first time, ramp-function
generator setting 1 is switched over to a ramp-up/down
times = 0
2
Ramp-up integrator operation:
When the setpoint is reached for the first time, ramp-function
generator setting 1 is switched over to generator setting 2 (P307
to P310)
3
Ramp-up integrator operation:
When the setpoint is reached for the first time, ramp-function
generator setting 1 is switched over to generator setting 3 (P311
to P314)

Ramp-function generator parameter set 1 (see also parameter P330)

P303
Ramp-up time 1
FDS
(G136)
P304
Ramp-down time 1
FDS
(G136)
P305
Lower transition rounding 1
FDS
(G136)
P306
Upper transition rounding 1
FDS
(G136)

Ramp-function generator parameter set 2 (see also parameter P330)

Ramp-function generator parameter set 2 is selected via the binector parameterized in P637.
P307
Ramp-up time 2
FDS
(G136)
P308
Ramp-down time 2
FDS
(G136)
P309
Lower transition rounding 2
FDS
(G136)
P310
Upper transition rounding 2
FDS
(G136)

Ramp-function generator parameter set 3 (see also parameter P330)

Ramp-function generator parameter set 3 is selected via the binector parameterized in P638.
P311
Ramp-up time 3
FDS
(G136)
10-40
Value range
[Unit]
Steps
-200.00 to 199.99
[%]
0.01%
-200.00 to 199.99
[%]
0.01%
0 to 3
1
0.00 to 650.00
[s]
0.01s
0.00 to 650.00
[s]
0.01s
0.00 to 100.00
[s]
0.01s
0.00 to 100.00
[s]
0.01s
0.00 to 650.00
[s]
0.01s
0.00 to 650.00
[s]
0.01s
0.00 to 100.00
[s]
0.01s
0.00 to 100.00
[s]
0.01s
0.00 to 650.00
[s]
0.01s
SIEMENS Energy & Automation
SIMOREG DC Master Base Drive Panel Operating Instructions
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 4
P052 = 3
FS=100.00
P051 = 40
Type: I2
Online
Ind: 4
P052 = 3
FS=-100.00
P051 = 40
Type: I2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: 4
P052 = 3
FS=10.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=10.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=10.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=10.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=10.00
P051 = 40
Type: O2
Online