Download  Print this page

Definition Of Simoreg Converter - Siemens 6RA70 Series Instructions Manual

Microprocessor-based converters from 15a to 1680a for variable speed dc drives.
Hide thumbs

Advertisement

PNU
Description
r059
Display of operating state
Meaning as for r000
10.4
Definition of SIMOREG DC MASTER converter
r060
Software version
Converter software release
(G101)
i001:
CUD
i002:
Slot D (board location 2)
i003:
Slot E (board location 2)
i004:
Slot F (board location 3)
i005:
Slot G (board location 3)
r061
Creation date of software
i001:
Year
(G101)
i002:
Month
i003:
Day
i004:
Hour
i005:
Minute
r062
Checksum
i001:
Converter firmware checksum
(G101)
i002:
Boot sector checksum
r063
Board code
Identification code of boards mounted in locations 1 to 3 of electronics box.
(G101)
1
i001:
Board in location 1
71: CUD1
72: CUD1 + CUD2
i002:
Board in slot D (upper slot of location 2)
111:
131 to 139:
141 to 149:
151, 152, 161: Special board (EB1, EB2, SLB)
i003:
Board in slot E (lower slot of location 2)
111:
131 to 139:
141 to 149:
151, 152, 161: Special board (EB1, EB2, SLB)
i004:
Board in slot F (upper slot of location 3)
111:
141 to 149:
151, 152, 161: Special board (EB1, EB2, SLB)
i005:
Board in slot G (lower slot of location 3)
111:
141 to 149:
151, 152, 161: Special board (EB1, EB2, SLB)
SIEMENS Energy & Automation
SIMOREG DC Master Base Drive Panel Operating Instructions
3
2
Arrangement of
board locations 1 to 3
F
D
and slots D to G in
electronics box
G
E
Pulse encoder board (SBP)
Technology board
Communications board
Pulse encoder board (SBP)
Technology board
Communications board
Pulse encoder board (SBP)
Communications board
Pulse encoder board (SBP)
Communications board
Value range
[Unit]
Steps
0.0 to 14.5
0.1
0.0 to 9.9
0.1
[SW 1.8 and later]
[SW 1.8 and later]
[SW 1.8 and later]
[SW 1.8 and later]
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: None
P052 = 3
Type: O2
Ind: 5
P052 = 3
Type: O2
Ind: 5
P052 = 3
Type: O2
Ind: 2
P052 = 3
Type: L2
Ind: 5
P052 = 3
Type: O2
10-13

Advertisement

   Also See for Siemens 6RA70 Series

   Related Manuals for Siemens 6RA70 Series

Comments to this Manuals

Symbols: 0
Latest comments:
  • Rolando Guevarra Jan 02, 2018 12:48:
    Hi, i have trouble in our drive, F019, anyone can help to solve this fault. Thanks in advance
  • vivek Kumar Jul 28, 2015 05:25:
    6ra70 drive 250 kw problem field weakning optimizati​on failed fault f050 fault valu 10 plz help... m
  • vk jadaun Jul 18, 2015 02:16:
    242 kw dc drive but problem optimizati​on fail 25 current and field fault F050 fault valu 3.... ... plz suggest...