Interpret Status Indicators

The operation panel contains six status indicators as defined in the following
table.
Table 25 - Status Indicator Legend
Status Indicators
Description
ON
PWM switching is being performed.
READY
OFF
PWM switching is not being performed.
ON
Fault occurred or the error log is being displayed.
FAULT
OFF
Normal operation
ON
The operation panel is in Program mode.
PROGRAM
OFF
The operation panel is in Monitor mode.
A
ON
The rms value (in Amps) of the monitored input current is displayed.
• AC input voltage (rms) value is displayed
V
ON
• DC-bus voltage value is displayed
ON
Monitored power-running (kW) value is displayed.
kW
Flashing
Monitored power (regenerated) (kW) value is displayed
The load ratio
A, V, kW
OFF
displayed when A, V, and kW are all OFF in Monitor mode.
(1) The displayed value of input current is only an approximate value and no accuracy can be guaranteed. If you need an accurate
value, measure it by using a dedicated measuring device.
The operation panel operates in the two modes:
• In Monitor mode, you can monitor various operating conditions
including input current of the 8720MC-RPS unit and DC-bus voltage,
for example.
• In Program mode, you can view and change parameter values, and
examine the error log.

Monitor Mode

To select a value to monitor, press
Pressing
or
increments you through the each of the displays.
In Monitor mode, the PROGRAM status indicator is OFF, indicating that the
operation panel is not in Program mode. When any fault occurs, the operation
panel cannot be changed to Monitor mode.
Rockwell Automation Publication 8720MC-RM001K-EN-P - September 2018
(1)
is a ratio of the input current to the rated current. Load ratio (in %) is
or
until the desired value is displayed.