Terminal Block Pinouts; Terminal Block Pinouts For 8720Mc-Rps065 Units - Allen-Bradley 8720MC-RPS065 User Manual

Regenerative power supply
Table of Contents

Advertisement

Terminal Block Pinouts

The 8720MC-RPS units have terminal blocks for making mains and control
power connections.

Terminal Block Pinouts for 8720MC-RPS065 Units

The 8720MC-RPS065 unit has two terminal blocks for mains and control
power connections.
Table 7 - Mains Power Terminal Connections
TB1
Description
G
Chassis ground
L1
L2
Three-phase input power
L3
N
DC bus connections to load equipment
P
Table 8 - Control Power Terminal Connections
TB2
Description
L1 AUX
L2 AUX
Three-phase AC input power to the control circuit.
L3 AUX
PR1
Precharge/discharge jumper:
• For internal resistor, apply jumper between PR2 and PR3
PR2
• For external resistor, apply jumper between PR1 and PR2
• For power regeneration mode only, remove jumper
PR3
MC1
Mains magnetic contactor
(rated for 250V AC/1 Amp or 30V DC/1 Amp).
MC2
Rockwell Automation Publication 8720MC-RM001K-EN-P - September 2018
Connector Data and Feature Descriptions
Signal
L1
L2
L3
DC–
DC+
Terminals
Control Power
Precharge/Discharge Resistor
Mains Magnetic Contactor
Chapter 4
35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents