Install The Varistor (8720Mc-Rps065 Units Only) - Allen-Bradley 8720MC-RPS065 User Manual

Regenerative power supply
Table of Contents

Advertisement

Chapter 5
Connect the 8720MC-RPS Unit
62
Table 20 - 8720MC Line Reactors for 8720MC-RPS065 Units
(1)
Line Reactors
Cat. No.
8720MC-LR03-032B
8720MC-LR05-048B
8720MC-LR10-062B
8720MC-LR14-070B
(1) Provide the required quantity of reactors for all units connected in parallel (refer to
Table 21 - 8720MC Line Reactors for 8720MC-RPS190 Units
(1)
Line Reactors
Quantity
Cat. No.
1
8720MC-LR10-100B
2
(1) Cooling fan and thermo switch are mounted on the line reactor unit. The thermo switch opens at about 150 °C (302 °F) and
produces a reactor-fan fault signal.
Table 22 - Wire Ratings for 8720MC Line Reactors
Line Reactors
Cat. No.
8720MC-LR03-032B
8720MC-LR05-048B
8720MC-LR10-062B
8720MC-LR14-070B
8720MC-LR14-070B
8720MC-LR10-100B
The operating ambient temperature for the 8720MC line reactors is 50 °C
(122 °F), maximum. Derate current 1% for every 1 °C above 50 °C.

Install the Varistor (8720MC-RPS065 units only)

Install a varistor to absorb surge voltage between AC input power wires. The
8720MC-VA-B varistor is the designated varistor for 8720MC-RPS065BM
and 8720MC-RPS065BS units.
IMPORTANT Provide the required quantity of varistors for all units connected in parallel
and connect the varistor on the incoming AC line-side of the AC contactor.
Rockwell Automation Publication 8720MC-RM001K-EN-P - September 2018
Continuous Current, max
Inductance
A
uH
32
850
48
800
62
1100
70
1200
Continuous Current, max
A
100
190
Continuous Current, max
≤60 A
60...80 A
Capacity of Motor, max
kW
15
22
30
37
Figure 23
and
Figure
24).
Inductance
Capacity of Motor, max
kW
uH
65
800
125
Wire Temperature
105 °C (221 °F) or higher
130 °C (266 °F) or higher
105 °C (221 °F) or higher

Hide quick links:

Advertisement

Table of Contents
loading