Mounting Guidelines - Allen-Bradley 8720MC-RPS065 User Manual

Regenerative power supply
Table of Contents

Advertisement

Chapter 3
Mount the 8720MC-RPS Unit

Mounting Guidelines

24
Observe the following guidelines when mounting 8720MC-RPS units in
parallel configurations:
• In configurations where one or two follower units are present, mount
the leader unit to the far right of the follower units
• Leader and follower units in the same configuration must be of the same
size and series. You cannot mix units of catalog number
8720MC-RPS065 with 8720MC-RPS190 and you cannot mix units of
series # with series B
• Mount 8720MC-RPS units according to the specified maximum
distance. This is required so that the connecting cables between
8720MC-RPS units reach from one unit to another
Figure 6 - 8720MC-RPS065 Leader and Follower Units
Follower Unit
8720MC-RPS065BS
Table 5 - Maximum Unit Spacing Specifications
8720MC-RPS
Cat. No.
8720MC-RPS065BM
8720MC-RPS065BS
ATTENTION: Leader and follower units in the same configuration must be of
the same size and series. You cannot mix units of catalog number
8720MC-RPS065 with 8720MC-RPS190 and you cannot mix units of series #
with series B. Failure to comply can result in damage to equipment.
Rockwell Automation Publication 8720MC-RM001K-EN-P - September 2018
Follower Unit
8720MC-RPS065BS
Maximum Spacing
8720MC-RPS (series #)
8720MC-RPS (series B)
mm (in.)
mm (in.)
250 (9.8
200 (7.9)
Leader Unit
8720MC-RPS065BM
Maximum Spacing

Hide quick links: