(377)
lay contacts and completes the power
circuit to the deck lock motor. The
deck lock motor is energized until
the top control switch is released.
TOP ERECT CYCLE
DECK LID UNLOCK
With the top control switch in the
top up position, current flows from
the top control switch, through the
top down limit switch, the right hand
deck open limit switch and the deck
unlock relay coil to ground (Fig.
1 0). The relay is energized, the
contacts are closed, and the power
I
PART 18-3-CONVERTIBLE TOP
circuit is completed to the deck lock
motor. The motor is energized and
the luggage compartment is unlocked.
DECK LID OPEN
As soon as the deck lid is un-
locked, the deck closed limit switch
contacts are repositioned (Fig. 11).
Now the current flows from the deck
open limit switch R.H., through
the deck closed limit switch, and
the deck open relay to ground. The
relay multiple contacts close and the
power circuits to the deck solenoid
valve and the top-deck motor are
TOP CONTROL SWITCH
PUSHED DOWN
TOP DOWN
18-17
completed. The deck solenoid valve
is energized and the hydraulic lines
are opened to the deck hydraulic
control cylinders. The top-deck motor
is energized and the deck lid is
opened. The deck lock motors con-
tinue to run until the deck is com-
pletely open.
TOP ERECT
When the deck lid is completely
opened, the deck open limit switch
R.H. plunger is depressed and the
switch contacts are repositioned (Fig.
TOP UNLOCK LIMIT SWITCH
White
TOP DOWN
RELAY
TO BATTERY
TERM~--~8~/u~e~---------------------~~--~8~/u~e---------+~~r-1
50-AMP
CIRCUIT BREAKER
TOP CONTROL SWITCH
0
Violet- White Stripe
FIG. 8-
Top Retrad- Top Retrad
Cycle
TOP DOWN
LIMIT SWITCH
Yellow-White Stripe
TOP SOLENOID (2)
TOP
DOWN
RELAY
N1225-B