18-14
GROUP 18-TRIM, SEATS, AND CONVERTIBLE TOP
(374)
reversible motor and pump. The hy-
draulic fluid pressure is controlled
by three electrically activated sole-
noid valves, two for the top assem-
bly, and one for the deck lid (Fig.
2).
ELECTRICAL COMPONENTS
The location and proper nomen-
clature for each electrical compo-
nent is illustrated in Fig. 3. The
TOP CONTROL SWITCH
PUSHED DOWN
50-AMP
CIRCUIT BREAKER
Blue
UP
TOP CONTROL SWITCH
o--
15-AMP
CIRCUIT BREAKER
function of these components is ex-
plained in detail with the circuits of
each phase of the retract and erect
cycle in Figs. 4 through 15.
TOP RETRACT CYCLE
DECK LID UNLOCK
With the top control switch in
the top down position (Fig. 4), cur-
rent flows from the top control switch,
through the upper back panel limit
DECK
OPEN
RELAY
Blue
Red
Orange-Brown Stripe
DECK
OPEN
RELAY
Yellow- Violet Stripe
Blue
Red
switch, the left hand deck open limit
switch (usually called deck open
limit switch L.H.), and the deck un-
lock relay coil to ground. The deck
unlock relay coil is energized, clos-
ing the relay contacts which com-
plete the power circuit from the 50-
ampere circuit breaker, through the
15-ampere circuit breaker to the deck
lock motor. The motor is energized
and the deck lid is unlocked.
DECK
SOLENOID
TOP AND DECK MOTOR
DECK LOCK MOTOR
DECK OPEN LIMIT SWITCH L.H.
Black
DECK CLOSED
LIMIT SWITCH
Yellow- Violet Stripe
Blue
Red-Blue Stripe
UPPER BACK PANEL
LIMIT SWITCH
0
0
DECK
UNLOCK
RELAY
Yellow-Red Stripe
Orange
DECK
SOLENOID
Black
DECK OPEN liMIT
SWITCH l.H.
0
0
N1222-B
FIG.
5-Deck Lid Open-Top Retrad
Cycle