Example Of Dio-403 Configuration - UEi RACKtangle DNR-12-1G Series User Manual

Data acquisition systems
Table of Contents

Advertisement

© Copyright 2018
United Electronic Industries, Inc.
DNR-X-1G Series RACKtangle and HalfRACK Systems
Figure 5-21. Example of DIO-403 Configuration
The Configuration tab gets/sets the current input/output directions per port. It
contains the following columns:
Name is the channel (port) name, or a user-defined string.
In/Out contains toggle switches to select whether all the channels in that
port are to be used as inputs or outputs.
Initialization/Shutdown tabs allow you to set initialization and shutdown states
on pins, as well as operation mode configuration. They contain the following
columns:
Name is the channel (port) name, or a user-defined string.
Mode specifies whether the channel is input or output.
7 through 0 contain the values 0 or 1. They are checkmarks for output
channels that allow you to select 0 (unchecked) or 1 (checked).
October 2018
Chapter 5
85
PowerDNA Explorer
www.ueidaq.com
508.921.4600

Hide quick links:

Advertisement

Table of Contents
loading