Field Replacement of Fuses on DNA and DNR Boards
Some boards used in UEI DAQ I/O systems require field replacement of fuses when unexpected overloads
occur. Locations of these fuses are shown in Figure B-1 through Figure B-3. Part numbers for the
replacement fuses are listed Table B-1.
Table B-1 DNA/DNR Replacement Fuses
UEI Fuse
UEI Part
ID (Board)
Rating
F1
5A
925-5125
F2
5A
925-5125
F3 (DC)
5A
925-5125
F3 (1GB)
10A
925-1125
F4
5A
925-5125
© Copyright 2018
United Electronic Industries, Inc.
DNR-X-1G Series RACKtangle and HalfRACK Systems

Appendix B

No.
Description
FUSE 5A 125V SLO SMD SILVER T/R
FUSE 5A 125V SLO SMD SILVER T/R
FUSE 5A 125V SLO SMD SILVER T/R
FUSE 10A 125V FAST NAN02 SMD
FUSE 5A 125V SLO SMD SILVER T/R
Figure B-1. Location of Fuse for Base Boards Equipped with a Fuse
October 2018
Mfr.
Littlefuse
Littlefuse
Littlefuse
Littlefuse
Littlefuse
5A 125V SLO SMD SILVER FUSE
UEI P/N 92505125
F1 (5A)
Appendix B
109
Mfr P/N
0454005.MR
0454005.MR
0454005.MR
0451010.MRL
0454005.MR
www.ueidaq.com
508.921.4600