2.2
DNR-12-1G
Specifi-
cations
© Copyright 2018
United Electronic Industries, Inc.
DNR-X-1G Series RACKtangle and HalfRACK Systems
Figure 2-2 lists the technical specifications of the DNR-12-1G PowerDNR
system.
Standard Interfaces
To Host Computer
Two independent 1000Base-T Gigabit Ethernet
ports (100/10Base-T compatible)
Distance from host
100 meters, max
Other Interfaces
One USB 2.0 controller port, One USB 2.0 slave
port.
Config/General
RS-232, 9-pin "D"
Sync
Custom cable to sync multiple racks
I/O Slots Available
DNR-12-1G
12 slots
Data transfer and communications rates
Ethernet data
20 megabytes per second
transfer rate
Analog data
up to 6 megasample per sec (16-bit samples)
transfer rate
DMAP I/O mode
update 1000 I/O channels
in less than 1 millisecond, guaranteed
Processor
CPU
Freescale 8347, 400 MHz, 32-bit
Memory
128 MB (not including on-board Flash)
Status LEDs
Power supplies within spec, One second system
heart-beat, Attention, Read/Write, Power, Com-
munications Active
Environmental
Temp (operating)
Tested to -40 °C to 70 °C
Temp (storage)
-40 °C to 85 °C
Humidity
0 to 95%, non-condensing
Vibration
(IEC 60068-2-64)
10–500 Hz, 3 g (rms), Broad-band random
(IEC 60068-2-6)
10–500 Hz, 3 g, Sinusoidal
Shock
(IEC 60068-2-27)
50 g, 3 ms half sine, 18 shocks at 6 orientations;
50 g, 11 ms half sine, 18 shocks at 6 orientations
MTBF
130,000 hours
Physical Dimensions
DNR-12 series
5.25" x 6.2" x 17.5" (3U in a 19" rack)
Power Requirements
Voltage
9 - 36 VDC (AC adaptor included)
Fuse
Internal 10 A
Power Dissipation
13 W at 24 VDC (not including I/O boards)
Power Monitoring
I/O board power
All internal power supplies monitored to ±1% ac-
curacy. All PS voltages may be read by host. LED
annunciators indicate out of range
Input current
Monitored by host, LED indicates overcurrent
Figure 2-2. DNR-12-1G Technical Specifications