6.4.7
Display Power
Diagnostics
Command
DQ> simod 5
DNR_PWR layer diagnostics
2.5DNR= 2.523*
24DNR=24.078*
1.2DNR= 1.294*
Temp2=25.063*
DNR_PWR_1G layer diagnostics
2.5DNx= 2.517*
3.3DNx= 3.315*
24DNx=24.249*
1.5DNx= 1.574*
VfanX= 0.022!
I 3.3= 0.752*
Temp1=31.998*
Unit logged 1146.0 hours
DQ>
© Copyright 2018
United Electronic Industries, Inc.
DNR-X-1G Series RACKtangle and HalfRACK Systems
Typing simod 5 at the serial prompt displays diagnostic information about the
DNR-X-1G Power and CPU boards. This diagnostic information includes actual
voltage readings on each of the 2.5V, 24V, 1.2V, 3.3V, and 1.5V supplies, as well
as actual temperature and current measurements.
2.5NIC= 2.511*
24NIC=24.164*
Vfan= 8.869*
GND1= 0.000*
U-Cap= 0.022*
Vin=23.896*
1.2DNx= 1.273*
Iin= 0.210*
I 1.5= 0.008!
Temp2=31.996*
Note that readings displayed under "DNR_PWR layer diagnostics" show
diagnostics for the DNR-POWER-DC Module (refer to Section 2.6 on page 17
for more information about this board).
Readings displayed under "DNR_PWR_1G layer diagnostics" show
diagnostics for the DNR-CPU/NIC Module (refer to Section 2.7 on page 21 for
more information).
October 2018
Programming CPU Board-specific Functions
3.3DNR= 3.322*
3.3NIC= 3.312*
Vin=22.717*
1.5DNR= 1.580*
Iin= 1.151*
Temp1=29.766*
Chapter 6
102
www.ueidaq.com
508.921.4600