Initial Boot-Up - UEi RACKtangle DNR-12-1G Series User Manual

Data acquisition systems
Table of Contents

Advertisement

4.2

Initial Boot-up

STEP 1: Familiarize yourself with your DNR system front-panel layout. Note that all
STEP 2: Optionally, set up communication over the serial port by attaching the serial
STEP 3: Connect power to the system (9-36V DC) by plugging the Molex-type power
STEP 4: Turn on the ON/OFF power switch at the front of the DNR-X-1G chassis.
© Copyright 2018
United Electronic Industries, Inc.
DNR-X-1G Series RACKtangle and HalfRACK Systems
Perform an initial boot in preparation for configuring the network using the
following procedure:
connections are made on the front of the unit; no rear access is required in a
rack-mounted configuration.
cable between the host PC and to the RS-232 port on the front panel of the
DNR-X-1G:
a. Run a serial terminal-emulation program (e.g., MTTTY) on the PC. Any
terminal-emulation program, except HyperTerminal, may be used
(MTTTY, Minicom, TeraTerm, PuTTY, etc.).
b. Verify that COM parameters are set at: 57600 baud, 8 bits, no parity, 1
stop bit.
c. Click Connect in MTTTY, or use the commands on one of the other
terminal-emulation programs to establish communication with the
DNR-X-1G system.
connector from the power supply into the mating connector at the front of the
DNR-X-1G chassis.
The power source may be the bundled DNA-PSU-180 180-watt (for DNR-12-
1G) or DNR-PSU-100 100-watt (for DNR-6-1G) powerbrick or a user-supplied
source. Note that the powerbrick plugs into a 100 - 240V, 47- 63 Hz outlet and
outputs up to 4.17A at 24 VDC.
NOTE: As soon as the system powers up, it runs through a self-diagnostic
mode and generates output on the terminal program. A typical readout
is shown in Figure 4-1 on the next page.
October 2018
Chapter 4
Installation and Configuration
www.ueidaq.com
508.921.4600
39