Stand-alone test procedures
Note: Subtract 0.50 dB per optical connection (for the suggested set-up 1.5 dB (3
connections)) and subtract 0.2 dB per fiber segment (0.4 dB for 2 fiber segments).
...................................................................................................................................................................................................
Disconnect the optical power meter and reconnect the fiber to the receive port of
12
LP1.1.
...................................................................................................................................................................................................
Remove the optical loop from the ODF and install a variable optical attenuator.
13
...................................................................................................................................................................................................
Increase the attenuation until the PDH analyzer reports single bit errors.
14
...................................................................................................................................................................................................
Decrease the attenuation a little until no errors are reported.
15
...................................................................................................................................................................................................
Wait approximately 5 minutes (no errors may occur).
16
...................................................................................................................................................................................................
Disconnect the fiber from the Line Port "input" at the physical NE port and measure
17
the optical output level (refer to
distribution frame test" (p.
...................................................................................................................................................................................................
Verify that the requirements mentioned in the table below are met.
18
Result:
Receiver sensitivity ranges:
Interface
S1.1
S1.1 (18 dB)
S4.1
L1.1
L1.2
L4.2
...................................................................................................................................................................................................
Repeat test for Line Port 2.1, if applicable.
19
E
N D
...................................................................................................................................................................................................
...................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
Wavelength [nm]
1310
1310
1310
1310
1550
1550
O F
S T E P S
Alcatel-Lucent - Proprietary
Line port connection to optical distribution frame test
Figure 7-2, "Line port connection to optical
7-9)).
See notice on first page
Receiver sensitivity [dBm]
≤ –28
≤ –34
≤ –28
≤ –34
≤ –34
≤ –28
7-11